Specifications; Heating Specifications; Calculation Of The Thermal Power - Nordica ROSA XXL UL-C Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

2.2 SPECIFICATIONS

Flue Gas outlet diameter in mm
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg

2.2.1 HEATING SPECIFICATIONS

Nominal power in kW
Efficiency in %
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Chimney draught MAX in Pa (mm H
Hourly wood consumption in kg / h
CO measured at 13% oxygen in %
Flue Gas emission in g/s – wood
Flue Gas temperature in °C - wood
Heatable volume in m
3
(30 kcal/h x m
(*) The proposed value are indicative. This appliance must be connected to (1) a listed Type HT (2100°F) chimney per UL 103 or ULC S629, or
(2) a code-approved masonry chimney with a flue liner. The chimney size should not be less than or more than three times greater than
the cross-sectional area of the flue collar.
(**) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of
the product is: favourable type of building (30 kcal/h x m
(50 kcal/h x m
).
3
(***) When the depression exceeds 15 Pa (=1.5 mm of column of water), it is necessary to reduce the same by installing an an
appropriate device on the exhaust pipe or in the chimney, according to the regulations in force.
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary
heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
The declared technical data have been achieved by burning beech wood class "A1" according to the requirement UNI EN ISO 17225-5 and
wood moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and some specific
adjustments on the appliance could be needed.

2.2.2 CALCULATION OF THE THERMAL POWER

There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the calorific value necessary for a properly insulated room is 30 kcal/h per m
external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 35 W/m
Let's suppose one wishes to heat a room of 150 m
W/m
= 5250 W or 5,25 kW. As main heating, a 8 kW device is therefore sufficient.
3
Fuel
Dry wood (15% humidity)
Wet wood (50% humidity)
Wood briquettes
Brown coal briquettes
Normal anthracite
Coke
Natural gas
Naphtha
Electricity
10
ROSA XXL UL-C
225 x 210
296 x 306 x 460
436 x 418 x 430
Movable - flat
ROSA XXL UL-C
(*) 4 - 200x200 Ø200
O)
12 (1,2 mm H
2
O)
(***)15 (1,5 mm H
2
0,08 - (1000 mg/Nm
)
3
244 (**)
); less favourable type of building (40 kcal/h x m
3
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
Approximate combustion value
Unit
kcal/h
kg
3600
kg
1850
kg
4000
kg
4800
kg
7700
kg
6780
m
7800
3
L
8500
kW/h
860
ROSA L UL-C
150
225 x 210
296 x 306 x 460
307 x 418 x 430
Movable - flat
861
1074
669
Chapter 2.1 DIMENSIONS
ROSA L UL-C
8,5
85
(*) 4 - 200x200 Ø200
O)
12 (1,2 mm H
2
O)
(***)15 (1,5 mm H
2
2,3
)
0,1 - (1212 mg/Nm
3
6,2
232
.
3
kW
4.2
2.2
5.0
5.6
8.9
7.9
9.1
9.9
1.0
MILLY UL-C
150
270 x 287 x 455
436 x 418 x 430
Movable - flat
861
975
670
MILLY UL-C
8,1
84
(*) 4 - 200x200 Ø200
O)
12 (1,2 mm H
2
O)
(***)15 (1,5 mm H
2
2,3
)
0,07 - (900mg/Nm
3
7
202
232 (**)
); unfavourable type of building
3
Required quantity in relation to
1 kg of dry wood
1,00
1,95
0,84
0,75
0,47
0,53
0,46
0,42
4,19
007098005-001
150
240 x 185
865
1050
670
8,7
89
O)
2
O)
2
2,3
)
3
5,8
180
249 (**)
3
(for an
x 35
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosa l ul-cMilly ul-c

Table of Contents