To light the fire, it is suggested to use small wood pieces together with paper or other traded lighting means.
Do not use an elevated grate or otherwise raise the fire.
The openings for air (primary and secondary) must be opened together (you must open the eventual Ignition control, and draught
valve placed on the pipe of smokes exhaust). When the wood starts burning, you may load other fuels and adjust the air for combustion
according to the instructions on paragraph TECHNICAL DESCRIPTION.
IT IS RECOMMENDED TO BUILD-UP AND MAINTAIN THE FIRE, AVOIDING ANY OVERFIRING (SEE CAP. TECHNICAL
DESCRIPTION / HOURLY CONSUMPTION). TOO MUCH FUEL AND TOO MUCH AIR FOR COMBUSTION CAN CAUSE
THE WARRANTY DOES NOT COVER THE DAMAGES DUE TO OVERHEATING OF THE EQUIPMENT.

6.1.1 LOW EMISSION FIRE LIGHTING

Smokeless combustion is a way of lighting a fire able to significantly reduce the emission of harmful substances. The wood burns
gradually from the top downwards, so combustion is slower and more controlled. Burnt gases pass through the high temperatures of
the flame and therefore burn almost completely.
Place the logs in the hearth a certain distance apart as shown in the
top, or vertically in the case of tall narrow combustion chambers. Place the fire starter module on top of the pile, arranging the first logs
in the module at right angles to the pile of wood.

6.1.2 FIRE STARTER MODULE

THIS FIRE STARTER MODULE REPLACES A PAPER OR CARDBOARD STARTER.
Prepare four logs, 20 cm long with a cross section of 3 cm by 3 cm as in the
Cross the four logs and place them on top of the pile of wood at right angles, with the
fire lighter (wax impregnated wood fibre for example) in the middle. The fire can be
lit with a match. If you want, you can use thinner pieces of wood. In this case, you will
need a larger quantity.
keep the flue gas exhaust valve and combustion air regulator open in the position as
shown in according to the instructions on paragraph TO IGNITE THE FLAME.
After lighting the fire, leave the combustion air regulator open in the position shown
in according to the instructions on paragraph TECHNICAL DESCRIPTION.
IMPORTANT:
DO NOT ADD FURTHER WOOD BETWEEN ONE COMPLETE LOAD AND THE NExT;
DO NOT SUFFOCATE THE FIRE BY CLOSING THE AIR INTAkES;
REGULAR CLEANING BY A CHIMNEY SWEEP REDUCES FINE PARTICLE EMISSIONS.
These instructions are suggested by ENERGIA Legno SvIZZERA
26
WARNING
PLEASE ALWAYS BE PRESENT DURING THIS PHASE.
OVERHEATING AND THEREFORE DAMAGE THE APPLIANCE.
Picture
. Arrange the largest at the bottom and the smallest at the
Picture
.