Chimney Connector System And Clearance From Combustible Walls Residential Heathing Appliances - Nordica ROSA XXL UL-C Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

3.2.7 CHIMNEY CONNECTOR SYSTEM AND CLEARANCE FROM COMBUSTIBLE WALLS
RESIDENTIAL HEATHING APPLIANCES
A
Minimum 3.5-in thick brick masonry all framed into
combustible wall with a minimum of 12-in brick
separation from clay liner to combustibles.
the fireclay liner shall run from outer surface of brick
wall to, but not beyond, the inner surface of chimney
flue liner and shall be firmly connected in place.
B
Solid-insulated,
listed
length of the same inside diameter as the chimney
connector and having 1-in or more of insulation with
a minimum 9-in air space between the outr wall of
the chimney length and combustibles.
C
Sheet steel chimney connector, minimum 24 gauge
in thickness, with a ventilated thimble, minimum
24 gauge in thickness, having two 1-in air channels,
separated from combustibles by a minimum of 6-in
of glass fiber insulation. Opening shall be covered,
and thimble supported with a sheet steel support,
minimum 24 gauge in thickness.
D
Solid insulated, listed factory-built chimney length
with an inside diameter 2-in larger than tha chimney
connector and having 1-in or more of insulation,
serving as a pass-through for a single wall sheet steel
chimney connector of minimum 24 gauge thickness,
with a minimum 2-in air space between the outer
wall of chimney section abd combustibles.
Minimum length of chimney section shall be 12-in
chimney section spaced 1-in away from connector
using sheet steel support plates on both ends of
chimney section supported on both sides with sheet
steel supports securely fastened to wall surfaces of
minimum 24 gauge thickness.
Fastners used to secure chimney section shall not
penetrate cheminey flue liner.
007098005-001
factory-built
chimney
Minimum chimney clearance from
masonry to sheet steel support and
combustibles 2 in. (51 mm)
Minimum
clearance 9 in.
(229 mm)
Chimney
connector
Adapter
Sheet steel
supports
Masonry chimney
constructed to
NFPA 211
Minimum chimney clearance from
masonry to sheet steel support and
combustibles 2 in. (51 mm)
Minimum 6 in.
(152 mm) glass
fiber insulation
Two air channels each
1-in (25.4 mm)
Chimney
connector
Sheet steel
supports
Minimum chimney clearance from
masonry to sheet steel support and
combustibles 2 in. (51 mm)
Minimum chimney
clearance 2 in. (51 mm)
Chimney
lenght
Chimney
connector
1-in (25.4 mm)
air space to
Sheet steel
chimney lenght
support
Masonry chimney
constructed to
NFPA 211
Minimum chimney clearance
to brick and combustibles 2 in.
(51 mm)
Minimum clearance
12 in. (305 mm)
of brick
Masonry chimney
constructed to
NFPA 211
Minimum 12in.
(305 mm)
to combustibles
Sheet steel
supports
Non-soluble
refractory
Factory built
cement
chimney lenght
Chimney lengh
flush with
inside of flue
Solid insulated listed
factory-built chimney
Air space 9 in.
lenght
(229 mm) min.
Two ventilated
air channels each
1-in (25.4 mm).
Construction of
sheet steel
Masonry chimney
constructed to
NFPA 211
Chimney
section
Chimney
connector
Air space 2 in.
(51 mm) min.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosa l ul-cMilly ul-c