3.0 INSTALLATION PLANNING

READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS APPLIANCE. FAILURE TO FOLLOW THE
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
USE ONLY APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED
ACCESSORIES AND REPLACEMENT PARTS (BLOWERS, DOORS, GASKETS, VENT COMPONENTS, ETC.) COULD RESULT IN A
THE COATING USED MUST BE NON-COMBUSTIBLE AND APPROVED ACCORDING TO STANDARD UL1618 FOR USA OR
Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and
Regulations and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the
law, being national, regional, provincial or town council present in the country within which the appliance is installed, besides these
present instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for final installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing flue of the house. The junction
must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing this appliance, carry out the following checks:
check where the flue gas connection is located on the appliance, i.e. UPPER - REAR - LATERAL
verify if your structure can support the weight of the appliance. In case of insufficient carrying capacity it is necessary to adopt
appropriate measures, La NORDICA responsibility is limited to the supply of the appliance (See chapter TECHNICAL DESCRIPTION).
Make sure that the floor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of flammable
material, provide suitable uL 1618 listed floor protector.
Make sure that there is adequate ventilation in the room where the appliance is to be installed, with particular attention to
windows and doors with tight closing (seal ropes).
Do not install the appliance in rooms containing collective ventilation ducts, hoods with or without extractor, type B gas appliances,
heat pumps, or other appliances that, operating at the same time, can put the room in depression.
Make sure that the flue and the pipes to which the appliance will be connected are suitable for its operation. It is NOT allowed the
connection of several appliances to the same chimney.
The diameter of the opening for connection to the chimney must at least correspond to the diameter of the flue gas pipe. The
opening must be equipped with a wall connection for the insertion of the exhaust pipe and a rosette.
The unused flue gas exhaust connection must be covered with its respective cap (see chapter DIMENSIONS).
The installation must be appropriate and has to allow the cleaning and maintenance of the product and the flue.
It is recommended to install smoke detectors.
Your authorized local chimney sweeper must be informed about the installation of the appliance so that he can check the correct
connection to the chimney.
THE COOK STOVES MUST BE INSTALLED WITH THE LEGS PROVIDED (IF APPLICABLE), ATTACHED AS SHOWN WITHIN
LA NORDICA S.P.A. DECLINES ALL RESPONSIBILITY FOR DAMAGE TO THINGS AND/OR PERSONS CAUSED BY THE SYSTEM.
WITHOUT AUTHORISATION AND EVEN LESS FOR THE USE OF NON ORIGINAL SPARE PARTS.

3.1 APPLIANCE mINImum CLEARANCE TO COmbuSTIbLES

When installing the product, the following safety measures must be observed:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components
flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with flammable structure (see
- distances A1, A2, and A3). All the minimum safety distances are shown on the product data plate and lower values
Picture 1
must not be used (see DECLARATION OF PERFORMANCE ).
b) In front of the furnace door, in the radiation area there must be non-flammable nor heat-sensitive objects or material closer than
- distance A1.
Picture 1
14
WARNING
SAFETY HAZARD AND WILL VOID THE WARRANTY.
APPROVED TO THE LOCALS CODES.
WARNING
THESE INSTALLATION AND OPERATING INSTRUCTIONS.
DO NOT OBSTRUCT THE SPACE BENEATH THE APPLIANCE.
IN ADDITION, IT IS NOT RESPONSIBLE FOR ANY PRODUCT MODIFIED
007098005-001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosa l ul-cMilly ul-c

Table of Contents