■Default settings

Item (Main display)
[rEF ] Reference condition
[Unit] Unit selection function
[F 0]
[NorP] SW output PNP/NPN setting
[i_o ] SW/external input setting
[oUt1] Output mode of OUT1
[1ot ] Switch operation of OUT1
[P_1 ] Set value of OUT1
[F 1]
[H_1 ] Hysteresis of OUT1
[dtH1] ON delay time
[dtL1] OFF delay time
[ CoL] Display colour of OUT1
[oUt2] Output mode of OUT2
[2ot ] Switch operation of OUT2
[P_2 ] Set value of OUT2
∗3
[F 2]
[H_2 ] Hysteresis of OUT2
[dtH2] ON delay time
[dtL2] OFF delay time
[CoL ] Display colour of OUT2
[F 3]
[FiL ] Digital filter setting
[F10]
[Sub ] Sub display
[F14]
[Cut ] Zero cut-off setting
[F20]
[inP ] External input setting
[F22]
[AoUt] Analogue output setting
[F30]
[SAvE] Accumulated value hold setting
[F80]
[diSP] Display OFF mode
[F81]
[P in ] Security code
[F90]
[ ALL] Setting of all functions
[F96]
[S_in] Check of input signal
[F98]
[tESt] OUT Output check
[F99]
[ini ] Reset to the default settings
∗1: This setting is only available for models with the unit selection function.
∗2: This setting is only available for models with the external input.
∗3:
Only available for models with switch outputs for OUT2.
∗4: This setting is only available for models with the analogue output.
Default settings (Sub display)
[ Std] Standard condition
∗1
[
L] L/min
Refer to the default settings of the switch output
PNP/NPN on page 35.
∗2
[ oUt] SW output
[ HYS] Hysteresis mode
[ 1_P] Normal output
50% of maximums rated flow range
[ 250] 250 L/min (500 L type)
[ 500] 500 L/min (1000 L type)
[1000] 1000 L/min (2000 L type)
5% of maximums rated flow range
[ 25] 25 L/min (500 L type)
[ 50] 50 L/min (1000 L type)
[ 100] 100 L/min (2000 L type)
[0.00] 0.00 s
[0.00] 0.00 s
[1SoG] Green when ON, Red when OFF (OUT1)
[ HYS] Hysteresis mode
[ 2_P] Normal output
50% of maximums rated flow range
[ 250] 250 L/min (500 L type)
[ 500] 500 L/min (1000 L type)
[1000] 1000 L/min (2000 L type)
5% of maximums rated flow range
[ 25] 25 L/min (500 L type)
[ 50] 50 L/min (1000 L type)
[ 100] 100 L/min (2000 L type)
[0.00] 0.00 s
[0.00] 0.00 s
[1SoG] Green when ON, Red when OFF (OUT1)
[ 1.0] 1.0 s
[ dEF] Standard (Set value of OUT1)
[ 1.0] 1.0%
∗2
[ rAC] Accumulated value reset
[ 1-5] 1 to 5 V (Analogue voltage type)
∗4
[4-20] 4 to 20 mA (Analogue current type)
[ oFF] Not held
[ oN] Normal display (Display ON)
[ oFF] Not used
[ oFF] Not used
No setting due to input signal setting
[
n] Normal output
[ oFF] Reset OFF
-34-
Page
Page
36
Page
39
Page
46
Page
52
Page
53
Page
59
Page
60
Page
61
Page
62
Page
63
Page
64
Page
66
Page
67
Page
68
Page
71
No.PF※※-OMZ0002

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf2mc7501Pf2mc7102Pf2mc7202

Table of Contents