■[F90] Setting of all functions
All functions can be set one after the other, without having to select each one separately from the function
selection mode.
<Operation>
Press the UP or DOWN button in function selection mode to display [F90].
Setting of all functions
Press the UP or DOWN button to select all functions.
[oFF] (Setting OFF)
is selected.
Press the SET button
to return to function
selection mode.
Order of function settings
Order
F number
1
F 0
2
F 1
3
F 2
4
F 3
5
F10
6
F14
7
F20
8
F22
9
F30
10
F80
11
F81
Press the SET button.
Return to [oFF] (Setting OFF),
then press the SET button to set.
Return to function selection mode.
[F90] Setting of all functions completed.
Items
Switching function of reference condition,
unit selection function, switch output specifications
Setting of OUT1
Setting of OUT2
Digital filter setting
Sub screen setting
Zero cut-off setting
Setting of external input
Setting of analogue output
Accumulated flow value hold setting
Display OFF mode setting
Setting of security code
Move on to setting of all functions.
Setting of functions.
-66-
[on] (Setting ON)
is selected.
Notes
All models
All models
SW2 output type
All models
All models
All models
Model with external input
function
Analogue output type
All models
All models
All models
No.PF※※-OMZ0002

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf2mc7501Pf2mc7102Pf2mc7202

Table of Contents