SMC Networks PF2MC7 Series Manual

SMC Networks PF2MC7 Series Manual

Digital flow switch
Hide thumbs Also See for PF2MC7 Series:

Advertisement

Quick Links

3-Color Display
Digital Flow Switch
Applicable fluid
3
-color/
Instantaneous flow rate
(Main screen)
Line name
(Sub screen/Left)
Set value
(Sub screen/Right)
Expanded flow range
A wide range of flow measurement is possible with 1 product.
100:1
Flow ratio ∗
2
∗2 Rated flow ratio is 10 : 1 for the existing PF2A series model.
Rated flow range [L/min]
1 2 5 10 20 25 50 100 150 200
5
500 L type
10
1000 L type
20
Smallest settable increment
5 L/min for the existing PF2A series model
PF2MC7 (-L)
3-Screen Display
Dry air, N
2
3
-screen display
∗1 3-screen display: 1 main screen and 2 sub screens (left/right)
300
500
600
1000
500
1000
2000
2000 L
type
1
L /min
Series
1
The flow rate value and the device status can be
figured out easily via the process data.
Diagnosis items
Over current error
Above the rated/
accumulated flow range
2000
Below the rated/
accumulated flow range
Internal product malfunction
New
New
RoHS
IP65
∗ For the PF2MC7 -L
Accumulated value
Peak/Bottom value
Line name
Compatible
2
p.
3-Screen Display
Digital Flow Monitor
Allows for the monitoring of
remote lines
PFG300
Series
CAT.ES100-146A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PF2MC7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks PF2MC7 Series

  • Page 1 3-Color Display 3-Screen Display Digital Flow Switch RoHS IP65 Applicable fluid Dry air, N ∗ For the PF2MC7 -L ∗ -color/ -screen display Accumulated value ∗1 3-screen display: 1 main screen and 2 sub screens (left/right) Peak/Bottom value Instantaneous flow rate (Main screen) Line name Line name...
  • Page 2 Digital Flow Switch 3-Color Display 3-Screen Display PF2MC7(-L) Series Clockwise ° Counterclockwise ° Rotary display Functions ( For details, refer to pages 24 and 25.) Delay time setting External input function Setting of a security code Display can be rotated in increments of Output operation Forced output function Peak/Bottom value display...
  • Page 3 Digital Flow Switch PF2MC7(-L) 3-Color Display 3-Screen Display Series IO-Link Compatible PF2MC7 - -L - Supports the IO-Link communication protocol IO-Link is an open communication interface Configuration File (IODD File * technology between the sensor/actuator and the I/O terminal that is an international ·...
  • Page 4 Digital Flow Monitor 3-Screen Display PFG300 Series Allows for the monitoring of remote lines PF3A7H Centralized flow control PFG300 For main line PFG300 PFG300 PFMB PFG300 PFG300 PF2MC The flow rate of a flow switch installed in a distant location can be confirmed! Visualization of settings The sub screen (label) shows the item...
  • Page 5: Convenient Functions

    Digital Flow Monitor PFG300 3-Screen Display Series NPN/PNP switch function Input range selection (for Pressure/Flow rate) The number of stock items can be reduced. The displayed value to the sensor input can be set as required. (Voltage input: 1 to 5 V/Current input: 4 to 20 mA) Pressure switch/Flow switch can be displayed.
  • Page 6 Flow Switch Flow Rate Variations Rated flow range [L/min] Applicable Detection Series fluid method −3 −2 −1 −0.5 PFMV Thermal Dry air type (MEMS) −0.5 −1 −3 Series Rated flow range [L/min] Smallest Applicable Detection settable Compatibility with the fluid method 5 10 20 25 50 100 150 200 300 500 600...
  • Page 7 Flow Switch Variations / Basic Performance Table PFMV PF2M7(-L) PFMB PF2MC7(-L) PF2A PF3A„H(-L) PFG300 PFMV3 PFG300 PFG300 IP65 IP65 IP40 IP40 IP40 IP65 [Monitor unit: IP40] [Monitor unit: IP40] Dry air, Dry air, N Dry air, N Dry air, N Air, N Air, N , Ar, CO...
  • Page 9 C O N T E N T S 3-Color Display 3-Screen Display Digital Flow Switch PF2MC7 Series 3-Color Display 3-Screen Display IO-Link Compatible Digital Flow Switch PF2MC7-L Series 3-Screen Display Digital Flow Monitor PFG300 Series 3-Color Display 3-Screen Display Digital Flow Switch PF2MC7 Series How to Order p.
  • Page 10: Color Display

    3-Color Display 3-Screen Display Digital Flow Switch PF2MC7 Series RoHS How to Order PF2MC Rated flow range Calibration certificate 5 to 500 L/min None 10 to 1000 L/min 20 to 2000 L/min *11 Made to order The certificate is in both English and Japanese.
  • Page 11: Screen Display

    3-Color Display 3-Screen Display Digital Flow Switch PF2MC7-L Series RoHS How to Order PF2MC Type Integrated display Rated flow range Calibration certificate 5 to 500 L/min None 10 to 1000 L/min 20 to 2000 L/min *9 Made to order The certificate is in both English and Japanese. Thread type Option 2 No bracket...
  • Page 12 PF2MC7(-L) Series For flow switch precautions and specific product precautions, refer to the “Operation Manual” on the SMC website. Specifications PF2MC7501 PF2MC7102 PF2MC7202 Model Dry air, N Applicable fluid Fluid (Air quality grade is JIS 8392-1 1.1.2 to 1.6.2, ISO 8573-1 1.1.2 to 1.6.2.) Fluid temperature range 0 to 50°C Detection method...
  • Page 13 3-Color Display 3-Screen Display PF2MC7(-L) Series Digital Flow Switch ∗1 When using the accumulated value hold function, use the operating conditions to calculate the product life, and do not exceed it. The number of times the memory device can be accessed is 3.7 million times. If the product is operated 24 hours per day, the product life will be as follows: ·...
  • Page 14: Flow Range

    PF2MC7(-L) Series Flow Range Flow range Model –100 L/min 0 L/min 200 L/min 500 L/min 1000 L/min 2000 L/min 5 L/min 500 L/min PF2MC7501(-L) 5 L/min 525 L/min –25 L/min 525 L/min 10 L/min 1000 L/min PF2MC7102(-L) 10 L/min 1050 L/min –50 L/min 1050 L/min 20 L/min...
  • Page 15 3-Color Display 3-Screen Display PF2MC7(-L) Series Digital Flow Switch Internal Circuits and Wiring Examples PF2MC7mmm-mm-Am-mmm PF2MC7mmm-mm-Bm-mmm NPN (2 outputs) type PNP (2 outputs) type Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 12 to 24 VDC 12 to 24 VDC White −...
  • Page 16 PF2MC7(-L) Series Internal Circuits and Wiring Examples PF2MC7m-mm-Lm-mm NPN output type PNP output type Brown Brown DC (+) DC (+) Black Black OUT1 OUT1 12 to 24 VDC 12 to 24 VDC White N.C. White N.C. Blue Blue DC (−) DC (−) Max.
  • Page 17 3-Color Display 3-Screen Display PF2MC7(-L) Series Digital Flow Switch Construction: Parts in Contact with Fluid Component Parts Description Material Note Sensor body Gasket HNBR Flow rectifier Stainless steel 304 Sensor chip Silicon Printed circuit board GE4F Gasket HNBR Body Aluminum alloy Anodized Mesh Stainless steel 304...
  • Page 18: Cable Specifications

    PF2MC7(-L) Series Dimensions PF2MC7501/7102/7202(-L) 2 x Port size (35.5) 2 x M3 x 0.5 depth 5 Symbol Port size Model PF2MC7501/7102(-L) Rc1/2, NPT1/2 60.6 41.2 13.6 PF2MC7202(-L) Rc3/4, NPT3/4, G3/4 66.1 46.7 17.5 16.8 PF2MC7501/7102(-L) G1/2 60.6 41.2 13.6 Bracket dimensions Symbol Model PF2MC7501/7102(-L)
  • Page 19: How To Order

    3-Screen Display Digital Flow Monitor PFG300 Series RoHS How to Order Type Remote type monitor unit Input specification Option 4 Symbol Description Applicable flow switch model Operation manual Calibration certificate Voltage input PF2MC7-C/E/L3 series —  Current input PF2MC7-D/F/L4 series —...
  • Page 20: Specifications

    PFG300 Series For flow switch precautions and specific product precautions, refer to the “Operation Manual” on the SMC website. Specifications PFG300 Model series Model PF2MC7501 PF2MC7102 PF2MC7202 Applicable SMC Rated flow range * flow switch 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow −25 to 525 L/min...
  • Page 21 PFG300 Series Digital Flow Monitor 3-Screen Display Internal Circuits and Wiring Examples NPN (2 outputs) + Copy function PNP (2 outputs) + Copy function qDC (+) qDC (+) Brown Brown DC (+) DC (+) Gray Gray Copy terminal Copy terminal rAnalog rAnalog input...
  • Page 22 PFG300 Series Dimensions Sensor connector 4 x ø2.6 (7.7) Depth 7 or less Power supply/Output connector Bracket A (Part no.: ZS-46-A1) 34.6 ∗ Bracket configuration allows for mounting in four orientations. Bracket B (Part no.: ZS-46-A2) ∗ Bracket configuration allows for mounting in four orientations.
  • Page 23 PFG300 Series Digital Flow Monitor 3-Screen Display Dimensions Panel mount adapter (Part no.: ZS-46-B) 50.8 34.5 20.2 47.8 Panel thickness 0.5 to 7 Panel mount adapter + Front protection cover (Part no.: ZS-46-D) 50.8 20.2 47.8 34.5 33.5 42.4 Panel thickness 0.5 to 7 Power supply/output connection lead wire Sensor connector (Part no.: ZS-46-5L)
  • Page 24 PFG300 Series Dimensions Panel fitting dimensions Individual mounting −0.4 Multiple (2 pcs. or more) secure mounting Panel mount example <Horizontal> <Horizontal> 31 x n pcs. + 3.5 x (n pcs. − 1) Panel mount example <Vertical> <Vertical> 24 or more −0.4...
  • Page 25: Function Details

    PF2MC7(-L) Series Function Details  Delay time setting  Response time (Digital filter) The time from when the instantaneous flow reaches the set value to The response time can be selected to suit the application. 0.05 s when the switch output operates can be set. Setting the delay time (Default setting: 1 s) 0.1 s can prevent the switch output from chattering.
  • Page 26 PF2MC7(-L) Series  Analog output free range function This function allows a flow that generates an output of 5 V (or 10 V when 0 to 10 V is selected) or 20 mA to be changed. The value can be changed between 10% of the max. value of the rated flow and the max.
  • Page 27 PFG300 Series Function Details  Output operation  Forced output function The output operation can be selected from the following: The output is forced ON/OFF when starting the system or during Output (hysteresis mode and window comparator mode) correspond- maintenance. This enables confirmation of the wiring and prevents ing to instantaneous flow or output (accumulated output and pulse system errors due to unexpected output.
  • Page 28 PFG300 Series  Selection of the display on the sub screen The display on the sub screen in measuring mode can be set. Set value display Accumulated value display Peak value display Displays the set value Displays the accumulated value Displays the peak value screen Bottom value display...
  • Page 29 PFG300 Series Function Details  Copy function The set values of the monitor can be copied. This can reduce setting labor and minimize the risk of setting mistakes. The set value can be copied to up to 10 flow monitors simultaneously. (Max.
  • Page 30: Safety Instructions

    These safety instructions are intended to prevent hazardous situations and/or Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for ∗1) safety and must be followed in addition to International Standards (ISO/IEC) and other safety regulations.

Table of Contents