●Product individual parameters (continued)
Index
Sub
Access
∗1
index
dec
hex
1
R/W
1300
0x0514
∗5
2
R/W
1
R/W
1310
0x051E
∗5
2
R/W
1
R/W
1410 0x0582
2
R/W
1
R/W
2
R/W
3
R/W
1420 0x058C
4
R/W
5
R/W
6
R/W
7
R/W
1
R/W
1500
0x05DC
∗5
2
R/W
1
R/W
1510
0x05E6
∗5
2
R/W
AC
1600 0x0640
0
R/W
(Setting of the accumulated
flow output direction)
FiL
1030 0x0406
0
R/W
(Digital filter)
Data
Initial
Parameter
type
value
∗2
AC1_L
U16
0
(Mantissa L)
AC1_L
U16
0
(Index L)
AC1_L
U16
0
3
(Mantissa Ft
)
AC1_L
U16
0
3
(Index Ft
)
oUt2
U8
0
(Selection output mode)
2ot
U8
0
(Selection of output type)
P_2 (n_2)
S16
2000
(Selection of output
set value)
H_2
S16
200
(Setting of OUT2
hysteresis)
P2L (n2L)
(Lower limit of
S16
1200
window
comparator)
P2H (n2H)
S16
2400
(Upper limit of
window comparator)
WH2
S16
400
(Window comparator
hysteresis)
dtH2
S16
0
(Delay time at ON)
dtL2
S16
0
(Delay time at OFF)
AC2_L
U16
0
(Mantissa L)
AC2_L
U16
0
(Index L)
AC2_L
U16
0
3
(Mantissa Ft
)
AC2_L
U16
0
3
(Index Ft
)
U8
0
U8
3
-84-
Data
∗4
storage
Set value
∗3
Setting range
Y
0 to 9999
Setting range
Y
0 to 6
Setting range
Y
0 to 9999
Setting range
Y
0 to 6
0: HYS (Hysteresis)
1: Wind
(Window comparator)
2: AC
Y
(Accumulated output)
3: PLS
(Accumulated pulse)
4: Err (Error output)
5: oFF (Output OFF)
0: 2_P (Normal output)
Y
1: 2_n (Reverse output)
Setting range
Y
-200 to 4200
Setting range
Y
0 to 4400
Setting range
Y
-200 to 4200
Setting range
Y
-200 to 4200
Setting range
Y
0 to 2200
Y
Setting range
0 to 6000
Y
Setting range
Y
0 to 9999
Setting range
Y
0 to 6
Setting range
Y
0 to 9999
Setting range
Y
0 to 6
0: Add (Addition)
1: dEC1
Y
(Subtraction OUT1)
2: dEC2
(Subtraction OUT2)
0:0.05 sec
1:0.1 sec
2:0.5 sec
Y
3:1.0 sec
4:2.0 sec
5:5.0 sec
Remarks
Setting of OUT1 mantissa
Unit: when "L" is selected
Setting of OUT1 index
Unit: when "L" is selected
Setting of OUT1 mantissa
Unit: when "Ft" is selected
Setting of OUT1 index
Unit: when "Ft" is selected
Setting of OUT2 output mode
Setting of OUT2 output normal and
reserved output.
Setting of OUT2 output set value
(Hysteresis)
Setting of OUT2 hysteresis
(Hysteresis)
Setting of OUT2 output set value
(Lower limit of window comparator)
Setting of OUT2 output set value
(Upper limit of window comparator)
Setting of OUT2 hysteresis
(Window comparator)
Setting of OUT2 delay time at ON
10 ms increment
Setting of OUT2 delay time at OFF
10 ms increment
Setting of OUT2 mantissa
Unit: when "L" is selected
Setting of OUT2 index
Unit: when "L" is selected
Setting of OUT2 mantissa
Unit: when "Ft" is selected
Setting of OUT2 index
Unit: when "Ft" is selected
Setting of the accumulated flow
output direction
Setting of digital filter
No.PF※※-OMZ0002