●Product individual parameters
Index
Sub
Access
∗1
index
dec
hex
Unit
1000 0x03E8
0
R/W
(Unit setting)
CoL
1010 0x03F2
0
R/W
(Selection of display colour)
NorP
1020 0x03FC
0
R/W
(Selection of switch output
PNP/NPN)
i_o
1030 0x0406
0
R/W
(select switch output/
external input)
rEF
1070 0x042E
0
R/W
(reference condition)
1
R/W
1210 0x04BA
2
R/W
1
R/W
2
R/W
3
R/W
1220 0x04C4
4
R/W
5
R/W
6
R/W
7
R/W
Data
Initial
Parameter
type
value
∗2
U8
0
U8
2
U8
1
U8
1
U8
1
oUt1
U8
0
(Selection output mode)
1ot
U8
0
(Selection of output type)
P_1(n_1)
S16
2000
(Selection of output
set value)
H_1
S16
200
(Setting of OUT1
hysteresis)
P1L(n1L)
(Lower limit of
S16
1200
window
comparator)
P1H(n1H)
S16
2400
(Upper limit of
window comparator)
WH1
S16
400
(Window comparator
hysteresis)
dtH1
S16
0
(Delay time at ON)
dtL1
S16
0
(Delay time at OFF)
-83-
Data
∗4
storage
Set value
∗3
0: L (L/min)
Y
1: Ft (cfm)
0: rEd (Constantly red)
1: Grn (Constantly green)
2: 1SoG
(OUT1 turns green at ON)
3: 1Sor
Y
(OUT1 turns red at ON)
4: 2SoG
(OUT2 turns green at ON)
5: 2Sor
(OUT2 turns green at ON)
0: NPN
Y
1: PNP
0: oUt (switch output)
Y
1: in (external input)
0: Std
(Standard condition)
Y
1: PNP
(reference condition)
0: HYS (Hysteresis)
1: Wind
(Window comparator)
2: AC
Y
(Accumulated output)
3: PLS
(Accumulated pulse)
4: Err (Error output)
5: oFF (Output OFF)
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
Setting range
Y
-200 to 4200
Setting range
Y
0 to 4400
Setting range
Y
-200 to 4200
Setting range
Y
-200 to 4200
Setting range
Y
0 to 2200
Y
Setting range
0 to 6000
Y
Remarks
When the unit selection function is
not included,
a read/write to an un-selectable item
is rejected.
Setting of display colour
Setting of switch output specification
Setting OUT2 output specification
setting
Measurement Units criteria setting
Setting of OUT1 output mode
Setting of OUT1 output normal and
reserved output.
Setting of OUT1 output set value
(Hysteresis)
Setting of OUT1 hysteresis
(Hysteresis)
Setting of OUT1 output set value
(Lower limit of window comparator)
Setting of OUT1 output set value
(Upper limit of window comparator)
Setting of OUT1 hysteresis
(Window comparator)
Setting of OUT1 delay time at ON
10 ms increment
Setting of OUT1 delay time at OFF
10 ms increment
No.PF※※-OMZ0002