Table 20: Standards And Rated Conditions For Rail Applications (En 50155) - WAGO 750-407/040-000 Manual

2-channel digital input; 220 vdc; 3 ms; extreme for wago-i/o-system 750 xtr
Hide thumbs Also See for 750-407/040-000:
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750 XTR
750-407/040-000 2DI 220V DC 3.0ms XTR
Table 19: EMC – Emission of Interference
Standard
Conducted Emission of Interference – Line Connection DC Voltage
• EN 61000-6-3
• EN 60255-26
• EN 55032 Class A
*)
QP = Quasi Peak Detector; AV = Average Detector
**)
If necessary, please find different data in the section "Approval" (regarding approval for
EMC A or EMC B).
Pos : 47.8 /Serie 750 (WAGO-I/O-SYST EM)/Ger ätebesc hrei bung (alte Str uktur)/Nor men und Richtlini en/Nor men und Ei ns atz beding ung en für Bahnanwendungen (EN 50155) XTR @ 28\mod_1486482984774_21.doc x @ 405384 @ @ 1

Table 20: Standards and Rated Conditions for Rail Applications (EN 50155)

4.1 Rated Operating Conditions
4.1.1 Altitude above sea level
4.1.2 Ambient operating temperature
4.1.3 Shock and vibration
4.1.4 Relative humidity
5.1 Power Supply
5.1.1.1 Master voltage fluctuations
5.1.1.2 Power interruptions
5.4 Surge, ESD, Burst Tests
5.5 EMC (Emission of Interference,
Immunity to Interference)
9.11 Materials (Fire Protection)
WAGO is a company certified in accordance with the IRIS quality standard.
Pos : 48 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Test Value
79 dB(µV) QP, 0.15 MHz ... 0.5 MHz
66 dB(µV) AV, 0.15 MHz ... 0.5 MHz
73 dB(µV) QP, 0.5 MHz ... 30 MHz
60 dB(µV) AV, 0.5 MHz ... 30 MHz
Minimum voltage
Maximum voltage
Device Description
*)
Class / Standard Compliance
AX (EN 50125-1)
TX
1A and 1B (EN 61373)
95 % (coated PCBs)
0.725 × U
n
1.3 × U
n
S1
EN 50121-3-2
EN 50121-3-2
EN 50121-4
EN 50121-5
EN 45545-2
Hazard level HL3
Version 1.3.0
31
Manual

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

2di 220v dc 3.0ms xtr

Table of Contents