NOTE: The factory configured passwords for all accounts on this device have been set
to the device serial number. In the event of a complete system reset, the passwords
convert to the default, which is extron for the Admin and User (see
Permissions Panel
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it performs the
command and sends a response to the host device. If the switcher is unable to perform
the command because the command is invalid or contains invalid parameters, the switcher
returns an error response to the host. The error response codes are:
E01
—
E10
—
E11
—
E12
—
E13
—
E14
—
E17
—
E18
—
E21
—
E22
—
E24
—
E25
—
E26
—
E28
—
NOTE: If the unit does not support or recognize the entered commands, no response is
issued.
on page 45 to change a password).
Invalid input number
Invalid command
Invalid preset number
Invalid output number
Invalid parameter
Invalid command for this configuration
Invalid command for signal type
System or command timed out
Invalid room number
Busy
Privileges violation (Ethernet only. Personnel logged in as users attempting
operations requiring administrator privileges. Users have access to all view
and read commands [other than the administrator password], and can create
ties and presets, and mute and unmute the output.)
NOTE: Commands give E24 if not administrator level.
Device not present
Maximum number of connections exceeded
Bad filename or file not found
FOX3 Matrix Series Switchers • SIS Configuration and Control