Switcher Error Responses; Using The Command/Response Tables - Extron electronics CrossPoint 450 Plus 84 HV User Manual

Table of Contents

Advertisement

im Vertrieb von

Switcher Error Responses

Using the Command/Response Tables

www.camboard.de
CAMBOARD Electronics
Amtnn•x
The switcher initiates the Amt message when an audio output mute is toggled on
or off from the front panel. "nn" is the output number, • is a space, and "x" is the
mute status: 1 = on, 0 = off.
Exen
The switcher initiates the Exe message when executive mode is toggled on or off
from the front panel. "n" is the executive mode status: 1 = on, 0 = off.
When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher is
unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (too large)
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this configuration
E17 — Timeout (caused only by direct write of global presets)
E21 — Invalid room number
E24 — Privilege violation (Ethernet, Extron software only)
The command/response tables begin on page 4-7. Lower case letters are acceptable
in the command field except where indicated for the gain and attenuation
commands. The table below shows the hexadecimal equivalent of each ASCII
character used in the command/response table.
ASCII to HEX Conversion Table
Space
Symbols are used throughout the table to represent variables in the command/
response fields. Command and response examples are shown throughout the
table.
Tel. 07131 911201
CrossPoint 450 Plus and MAV Plus Switchers • Programmer's Guide
Fax 07131 911203
ce-info@camboard.de
4-5

Advertisement

Table of Contents
loading

Table of Contents