User Codes in the Ademco/Honeywell Panel
Because the communicator duplicates the panel's user codes, existing user codes in the Ademco/Honeywell panel,
including master, must be added to the communicator. Any new user codes added to the communicator from the
Virtual Keypad app will be automatically entered in the Ademco/Honeywell panel.
User codes from the Ademco/Honeywell panel that are designated as master or partition master should be configured
as master codes in the communicator.
If the Ademco/Honeywell panel is armed/disarmed from a keypad, the communicator reports an opening/closing
message by user 0 to the central station.
When the communicator is armed by the Virtual Keypad app or VirtualKeypad.com, the Ademco/Honeywell panel
is also armed and the communicator reports an opening message. If opening and closing reports are enabled in the
Ademco/Honeywell panel, a duplicate message will also be sent to the central station.
Note: Communicators with Version 194 and higher do not require you to log in to the VISTA panel with a master
code to manage user codes remotely.
BLACK
RED
1
Digital Monitoring Products
10
(USE SA4120XM-1
1 2 3 4 5 6 7 8
CABLE)
SYNC
COM
DATA
-
+
Ademco Vista 20P
2
3
4
5
6
7
8
9
-
+
+
J1
J8
B
R
Figure 8: Ademco Vista 20P ECP to iComSL
iCom Series Universal Alarm Communicator Programming and Installation Guide
VISTA 20P ONLY
10
11
12
13
14
15
16
17
18
19
20
S1
RESET
S2
LOAD
J9
S3
21
22
23
24
25
TIP
RING
TIP
RING
(BROWN)
(GRAY)
(GREEN)
(RED)
Need help?