Updown Test; Inverter Test; Manual Inverter Test; Manual Updown Test - Technogym ACTIVE Wellness TV RUN EXCITE Machine Configuration

15" display
Table of Contents

Advertisement

1.10.5. U
D
P
OWN
The UpDown test checks whether the number of pulses output by the encoder corresponds to the
values of the UpDown table stored in the low kit. During the test, the machine incline is moved
from 0 to 15% (18% on 900 model) and then back to 3%. Each incline position is converted into a
number of pulses and compared with the value in the UpDown table.
During the test the elevation value is displayed on the screen and the machine stops for a couple of
seconds when reach the elevation of 0%, 15% and finally 3%when it's moving down.
The test can have two outcomes:
• "DC Error (Up/Down)": The message indicates that the values do not correspond. The specific
message (Up or Down) indicates whether the error occurred during the upward (Up) or
downward (Down) movement of the test.
• "Test Successful": This message indicates that the test was completed without errors.
1.10.6. I
NVERTER
The inverter test checks the condition of the AT driver. The test can have two outcomes:
• "Test Successful": This means that the test was completed successfully and the inverter is not
in an error condition.
• "Inverter Error": This means that the test was not completed successfully, i.e. that the serial
link is inactive and/or the inverter is in an error condition.
1.10.7. M
ANUAL
The manual inverter test displays the values output by the inverter drive during movements of the
tread belt motor. The values displayed are:
• Tread belt motor drive frequency (Hz);
• Speed (Km/h);
• Current (A);
• Voltage (V).
During the test it is possible to vary the speed using the + and – speed keys, to check that the values
vary accordingly.
1.10.8. M
ANUAL
The manual UpDown test displays the values output by the elevation motor drive during machine
incline movements. The values displayed are:
• Machine incline position;
• Number of pulses generated by the elevation motor encoder;
• State of limit switch: if it is pressed, "M12" is shown, otherwise "M2".
During the test it is possible to vary the incline using the ↑ and ↓ elevation keys, to check that the
values vary accordingly.
Page 32
T
EST
T
EST
I
T
NVERTER
EST
U
D
T
P
OWN
EST
ACTIVE WTV: Machine configuration

Advertisement

Table of Contents
loading