Technogym ACTIVE Wellness TV RUN EXCITE Machine Configuration page 16

15" display
Table of Contents

Advertisement

Error
Error
code
number
OH
1
OC
2
UU
3
OU
4
PE
6
EdC1
7
EdA
8
OtM
9
Oli
10
OLm
11
OLr
12
Ot
13
OCH
16
MST
17
EM
19
SHC
23
Press HOME to confirm and save, FORWARD or BACK to scroll the pages.
Page 12
Description
Overheating of the heat sinks of the AT drive and of the PFC.
Overcurrent, even if only transient, on the inverter output.
Undervoltage condition, due to an even transient drop in line voltage.
Overvoltage.
EEPROM error. Is generated when there is an error detected in the data
stored on the EEprom.
Elevation motor encoder error.
AC motor encoder error.
AC motor thermal cutout open.
Inverter overload caused by a DC current exceeding, for the maximum
2
allowed time (I
t), the maximum permissible threshold for the inverter.
Motor overload caused by a DC current exceeding, for the maximum
2
allowed time (I
t), the maximum permissible threshold for the motor in
question.
Braking resistor overload.
Over-torque due to an even momentary overload of the inverter. Is
generated when the torque output of the motor exceeds a pre-established
limit for a pre-established time.
HW overcurrent.
Motor lockout which occurs, operating in closed loop mode with the
encoder active, if the inverter fails to reach the target speed even after
attempting to reduce the reference frequency.
Emergency. Is generated when the AT drive receives a software
emergency signal that is not accompanied by a hardware emergency
signal.
Short Circuit. Is generated in the event of a short circuit between a motor
phase and earth.
ACTIVE WTV: Machine configuration