Low Kit Parameter; Read From Low Kit; Write To Low Kit; Default Setting - Technogym ACTIVE Wellness TV RUN EXCITE Machine Configuration

15" display
Table of Contents

Advertisement

ACTIVE WTV: Machine configuration
1.2.1.
L
OW KIT PARAMETER
This function provides access to parameters used for modifying certain settings of the lower
assembly. To access this menu, when the display shows:
In addition to the 13 configuration parameters, this function also includes the 3 sub-functions
described below:
1.2.1.1.

Read from low kit

To read the parameter values from the low kit memory and view them on the display, press READ
FROM LOW KIT key.
1.2.1.2.

Write to low kit

To write the values of the currently displayed parameters to the low kit, press WRITE TO LOW
KIT key.
1.2.1.3.

Default Setting

To load the default parameter values, press DEFAULT SETTING key.
1.2.1.4.

Table of configuration parameters

To correctly display the parameter values, you need to load them from the low kit, using
the "Read from low kit" function.
Parameter Description
Par 01
Default
[Km/h*10]
Par 02
Default acceleration and deceleration for tread
belt motor. [Km/h*100/sec]
Par 03
Default zero reference position for tread-belt
incline. [*2]
Par 04
PID proportional gain. [*100]
Par 05
PID Integral gain. [*100]
Par 06
Ramp Type
Par 07
Error status on DC motor encoder
Par 08
Serial communication timeout [10*msec]
speed
for
Quick
Range
Start
workout.
0 - 300
0 - 3000
-10 - +40
0 - 9999
0 - 9999
0 - 100
0 - 1
0 - 255
Default value
8
100
0
7
150
0
0
0
Page 9

Advertisement

Table of Contents
loading

Table of Contents