Connect Venting - Valor G4 Series Installation & Owner's Manual

Direct vent gas insert fireplace
Table of Contents

Advertisement

Connect Venting

IMPORTANT: This appliance's venting system is room sealed and
therefore, does not require room air to be used in the combustion process.
1. Rough-in two 3" diameter vent liners into the existing chimney
system from the roof. Be careful not to tear or damage the liners in
the process. It may be easier to install both liners at the same time
rather than one at a time. Leave plenty of liners at the bottom to
facilitate the connection of the liners to the vent slider. It is best to
leave the top termination until later.
Designate and mark the top and bottom of one liner as
"EXHAUST" to avoid confusion later.
2. Release the two screws retaining the vent slider to the front of the
fi rebox. Remove the slider from the fi rebox by sliding it towards the
back of the fi rebox.
3. Fit the two liners ensuring that the exhaust liner is connected
to the identifi ed "EXHAUST" vent collar. Secure liners to collars
with hose clamps (included) and 2 tapping screws per liner.
4. Slide the fi rebox onto the vent slider in the cavity taking care not to
damage the liners. Make sure that the rear edge of the slider is
hooked over the cleat on the fi rebox. Secure the vent slider to the
front of the fi rebox with two screws removed earlier.
5. From the roof, pull the liners and fi t the fl ashing.
6. Fit the terminal cap ensuring that the exhaust liner is connected
to the exhaust vent collar. Secure with screws.
7. Seal the terminal and fl ashing from water penetration as required.
WARNING
WARNING
!
Failure to position the parts in
accordance with these diagrams
or failure to use only parts
specifi cally approved with this
appliance may result in property
damage or personal injury.
Installation
Vent slider
cleat
7
2
4
QUALIFIED
INSTALLER
6
5
1
3
27