Maximum Ratings; Ambient Conditions And Classifications - PI PIMAG V-412.xx6025E0 Series User Manual

High-load linear stage
Table of Contents

Advertisement

12 TECHNICAL DATA
Miscellaneous
Operating Temperature
Range
Material
Overall mass
Moved mass
MTBF
Connector
Purge air system
Recommended controllers
12.2

Maximum Ratings

The V-412.xx6025E0 is designed for the following operating data:
Maximum operating voltage Maximum operating fre-
300 V
12.3

Ambient Conditions and Classifications

The following ambient conditions and classifications for the V-412.xx6025E0 must be
observed:
30
V412M0008EN ‒ 5/11/2020
V-412
5 to 40
Aluminum, black anodized
stainless steel
V-412.03 (52 mm travel range): 5.0
V-412.05 (102 mm travel range): 5.6
V-412.09 (204 mm travel range): 6.7
V-412.13 (305 mm travel range): 7.9
V-412.17 (407 mm travel range): 9.0
V-412.21 (508 mm travel range): 10.2
V-412.25 (610 mm travel range): 11.3
1.7
20000
M15 (motor)
M15 (linear encoder)
Fitting for purge air hose with outside diame-
ter 4 mm
Operating pressure: 2 to 6 bar (200 to 600
kPa)
Relative humidity: < 70 %
Absolute humidity: < 35 g/m
ACS modular controller
quency
Unit
°C
kg
kg
h
3
Maximum peak current, RMS
10.6 A
M O T I O N | P O S I T I O N I N G
Toler-
ance
±5 %
±5 %