6 INSTALLATION
4. Make sure that the contact resistance is <0.1 Ω at 25 A at all points relevant for attaching
the protective earth conductor.
6.3

Building a Multi-Axis System

The V-412.xx6025E0 can be used in XY systems.
Designations in these instructions:
■ Lower positioner: Forms the basis of the multi-axis system, is attached to an underlying
surface
■ Upper positioner: Forms the upper axis of the multi-axis system, is attached to the lower
positioner rotated by 90°
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the V-412.xx6025E0.
► Pay attention to the
V-412.xx6025E0.
► Only use screws and locating pins of the correct length for the respective mounting holes.
Building a Multi-Axis System
1. Turn the upper positioner 90° and mount it onto the lower positioner.
Proceed as described under
6.4

Mounting the Load onto the V-412.xx6025E0

Overview
2
3
Figure 8: Mounting the load onto the V-412.xx6025E0
1. Screws
2. Load
3. Motion platform of the V-412.xx6025E0
Tools and Accessories
■ At least 3 screws with suitable
18
V412M0008EN ‒ 5/11/2020
depth of the mounting and locating holes (p. 32)
Mounting the Load onto the V-412.xx6025E0 (p.
1
1
1
1
dimensions (p. 32)
in the
18).
M O T I O N | P O S I T I O N I N G