6 INSTALLATION

6
Installation
6.1

Mounting the V-412.xx6025E0

Overview
Figure 6: Mounting the V-412.xx6025E0 onto an underlying surface
Tools and Accessories
Screw set for mounting the V-412.xx6025E0 (p. 10)
■ Suitable screwdriver
Requirements
You have read and understood the
You have provided a suitable surface with the holes necessary for the
required, locating pins (p.
■ The flatness of the surface is ≤ 2 μm.
■ For applications with large temperature changes: The surface should have the same or
similar thermal expansion properties as the V-412.xx6025E0.
You have accounted for the space required to route cables without bending and
according to regulations.
CAUTION
Risk of crushing by moving parts!
Risk of minor injuries from crushing between the moving parts of the V-412.xx6025E0 or the
load and a fixed part or obstacle.
► Use safeguards to protect limbs in areas where they could be caught by moving parts.
► Maintain the safety distances according to DIN EN ISO 13857 when installing protective
structures.
15
V412M0008EN ‒ 5/11/2020
general safety instructions (p.
31).
7).
screws and if
M O T I O N | P O S I T I O N I N G