B. Installation Requirements
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do
not derate this appliance for altitude. Maintain the manifold
pressure at 3.5" w.c. for Natural Gas, and 10" w.c. for
Propane).
In Canada, installation must be in accordance with the current
CSA B-149.1 Installation Codes and/or local codes.
The installation should be done by a qualified service person
who is familiar with the building codes and installation
techniques appropriate for your area to accomplish a safe
and effective installation.
Your dealer or your local gas supplier will be able to refer a
qualified service person.
!
Due to high temperatures, the heater should be located
out of traffic and away from furniture and draperies.
The surface of the Heater Is hot when it is in use. Young
children should be watched carefully when they are in the
same room when the Heater is in use, and they should
be taught to avoid the hot surface. Keep any objects that
can burn well away from the Heater, and observe the
recommended clearances that follow.
!
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information consult a qualified installer, service
agency or the gas supplier.
In choosing a location for the stove, consider:
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements.
NOTE: We do not recommend the use of wallpaper next to
this stove. Over time, radiant heat may cause the wallpaper
to shrink, or may adversely affect the binders in the wallpaper
adhesive.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
* Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
66
WARNING
WARNING
Vermont Castings • Intrepid DV-IFT Owner's Manual_R20 • 11/21
Direct Vent System Only
A
E
A. Flat on corner wall
B. Room Divider
ST207a
C. Island
Stardance
Stove locations
Figure 2.2 - Possible stove locations.
9/28/00 djt
C. Clearance Requirements
Minimum Clearances to Combustible Materials
Measure side clearances as shown in Figures 2.3 thru 2.6
from the outer edge of the cast iron stove top. Measure rear
clearances from the outermost surface of the steel rear skirt.
The Intrepid DV heater is approved for installation into
an alcove constructed of combustible materials to the
dimensions and clearances shown on the next page.
The same clearances apply in a standard parallel installation.
!
Always maintain minimum clearances around vent
systems. Rear/Top Vent Vertical Side wall: Horizontal
sections of this vent system require a minimum of 3" (76
mm) clearances to combustibles at the top of the flue and
1" (25 mm) clearance at the sides and bottom until the flue
penetrates the outside wall. A minimum 1" clearance all
around the flue is acceptable at this point of penetration.
If vertical rise is 7-1/2 feet (2.3 m) or higher when top
venting, the clearance to combustibles is 1" on all sides of
the horizontal run. FOR VERTICAL RUNS ONLY, maintain
a 1" (25 mm) minimum clearance to all sides. Do not pack
the open air spaces around the stove or flue with insulation
or other materials. Any horizontal run must have a 1/4" rise
for every one (1) foot of run towards the vent termination.
Never run the vent level or down.
D
B
C
D. Cross Corner
E. Flat on wall