Installation Requirements; Clearance Requirements - Vermont Castings SDDVTBSSB Installation And Operating Instructions Manual

Sddvt series stardance direct vent gas heater
Hide thumbs Also See for SDDVTBSSB:
Table of Contents

Advertisement

PRE-INSTALLATION

INSTALLATION REQUIREMENTS

The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 – latest edition. (EXCEPTION: Do
not derate this appliance for altitude. Maintain the mani-
fold pressure at 3.5" w.c. for Natural Gas, and 10" w.c. for
Propane).
In Canada, installation must be in accordance with the
current CSA B-149.1 Installation Codes and/or local codes.
The installation should be done by a qualified service
person who is familiar with the building codes and instal-
lation techniques appropriate for your area to accomplish
a safe and effective installation.
Your dealer or your local gas supplier will be able to refer
a qualified service person.
WARNING
Due to high temperatures, the heater should be located
out of traffic and away from furniture and draperies.
The surface of the heater Is hot when it is in use. Young
children should be watched carefully when they are
in the same room when the heater is in use, and they
should be taught to avoid the hot surface. Keep any
objects that can burn well away from the heater, and
observe the recommended clearances that follow.
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
In choosing a location for the stove, consider:
DANGER
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements.
NOTE: We do not recommend the use of wallpaper
next to this stove. Over time, radiant heat may cause
the wallpaper to shrink, or may adversely affect the
binders in the wallpaper adhesive.
Une barrière visant à réduire le risque de brûlure
par le hublot chaude est fournie avec cet
66
appareil et doit être installé.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Un panneau vitré chaud peut
causer des brûlures.
Laissez refroidir le panneau
vitré avant d'y toucher.
Ne laisser jamais les enfants
toucher le panneau vitré.
Stardance
Direct Vent System Only
A
E
A. Flat on corner wall
B. Room Divider
ST207a
C. Island
Stardance
Stove locations
Figure 2 Possible stove locations.
9/28/00 djt

CLEARANCE REQUIREMENTS

Minimum Clearances to Combustible Materials
Measure side clearances as shown in Figures 3, 4 and 5
from the outer edge of the cast iron stove top. Measure
rear clearances from the outermost surface of the steel
rear skirt.
The Stardance heater is approved for installation into an
alcove constructed of combustible materials to the dimen-
sions and clearances shown on the next page.
The same clearances apply in a standard parallel instal-
lation.
WARNING
• Always maintain required clearances (air spaces) to
nearby combustibles to prevent fire hazard. Do not
fill air spaces with insulation. All venting components
must maintain a 1" (25 mm) clearance to combusti-
ble materials.
• The gas appliance and vent system must be vented
directly to the outside of the building and never be
attached to a chimney serving a separate solid fuel
or gas-burning appliance.
• Refer to the manufacturer's instructions included
with the venting system for complete installation pro-
cedures.
Direct Vent Gas Heater
®
D
B
C
D. Cross Corner
E. Flat on wall
20306760

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents