Vermont Castings Intrepid INDVRBDSB Installation & Operating Manual
Vermont Castings Intrepid INDVRBDSB Installation & Operating Manual

Vermont Castings Intrepid INDVRBDSB Installation & Operating Manual

Direct vent gas heater
Hide thumbs Also See for Intrepid INDVRBDSB:

Advertisement

Quick Links

Installation & Operating Manual
Installation and Appliance Setup - Care and Operation
,167$//(5 /HDYH WKLV PDQXDO ZLWK SDUW\ UHVSRQVLEOH IRU XVH DQG RSHUDWLRQ
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
®
Intrepid
Direct Vent Gas Heater
Model: INDVRBDSB, INDVRCBSB,
INDVR-IFT-CB, & INDVR-IFT-BD
CERTIFIED
S
B
AFETY
ARRIER
Installation and service of this appliance should be performed by
TXDOL¿HG SHUVRQQHO +HDUWK
++7 )DFWRU\ 7UDLQHG RU 1), FHUWL¿HG SURIHVVLRQDOV
11
+RPH 7HFKQRORJLHV UHFRPPHQGV
Vermont Castings • Intrepid DV-IFT Owner's Manual_R27 • 06/23
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death or property damage.
'R QRW VWRUH RU XVH JDVROLQH RU RWKHU ÀDPPDEOH
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use
DQ\ SKRQH LQ \RXU EXLOGLQJ
± /HDYH WKH EXLOGLQJ LPPHGLDWHO\
– Immediately call your gas supplier from a
QHLJKERU¶V SKRQH )ROORZ WKH JDV VXSSOLHU¶V
instructions.
– If you cannot reach your gas supplier, call the
¿UH GHSDUWPHQW
,QVWDOODWLRQ DQG VHUYLFH PXVW EH SHUIRUPHG
E\ D TXDOL¿HG LQVWDOOHU VHUYLFH DJHQF\ RU WKH
gas supplier.
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and must be installed.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
3-90-30007474

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Intrepid INDVRBDSB

  • Page 1 UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 2 - 2SHUDWLRQ 'XULQJ D 3RZHU 2XWDJH  ,QWHOOL)LUH Touch  43 . 'HWDLOHG &RPSRQHQW 2SHUDWLQJ ,QVWUXFWLRQV IntelliFire™ Touch44 / )UHTXHQWO\ $VNHG 4XHVWLRQ IntelliFire 7RXFK &RQWUROV ,)75& 46 0 7URXEOHVKRRWLQJ47 1 %XUQHU 3LORW &RQWURO &RPSDUWPHQW49 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 3 This appliance may be installed in an aftermarket* manufactured Verify proper operation after servicing. PRELOH KRPH ZKHUH QRW SURKLELWHG E\ VWDWH RU ORFDO FRGHV * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 4: California Safety Information

    YHQWHG JDV IXHOHG HTXLSPHQW VKDOO QRW DSSURYH WKH LQVWDOODWLRQ unless, upon inspection, the inspector observes carbon PRQR[LGH GHWHFWRUV DQG VLJQDJH LQVWDOOHG LQ DFFRUGDQFH ZLWK WKH SURYLVLRQV RI  &05   D  WKURXJK  Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 5 32-1/4” (819mm) 21-3/16” (538mm) 13-11/16 (347mm) 21-3/8" 24-1/4” (543mm) (616mm) Centerline of Flue Pipe 18” (457mm) Valve Inlet 4” (102mm) 21-3/4” (553mm) 13-7/8” (352mm) Figure 2.1  ,QWUHSLG '9 GLPHQVLRQV Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 6: Installation Requirements

    This appliance is not FRQYHUWLEOH IRU XVH ZLWK RWKHU JDVHV XQOHVV D FHUWL¿HG kit is used. $IWHUPDUNHW &RPSOHWLRQ RI VDOH QRW IRU SXUSRVH RI UHVDOH IURP WKH PDQXIDFWXUHU Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 7: Hearth Requirements

    4” 4” 2" (51 mm) Min. Height = 69-3/4”, Min. Width = 33-3/16”, Max. Depth = 18-15/16” Figure 2.7  $OFRYH &OHDUDQFHV Figure 2.4  &RUQHU LQVWDOODWLRQ PLQLPXP FRUQHU FOHDUDQFHV Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 8: Vent Terminations & Clearances

    Refer to this manual for correct installation and operational procedures. For assistance or additional Figure 2.8  +RUL]RQWDO YHQW WHUPLQDWLRQ ZLQGRZ LQIRUPDWLRQ FRQVXOW D TXDOL¿HG LQVWDOOHU VHUYLFH agency, or the gas supplier. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 9 SLSH 6HH WKH PDNHU¶V LQVWUXFWLRQV IRU UHFRPPHQGHG installation procedures. 1 FLUE RESTRICTOR 10 11 12 13 14 15 16 17 18 19 Horizontal Run (in feet) Figure 2.9  9HUWLFDO YHQW WHUPLQDWLRQ ZLQGRZ Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 10 YHQWLQJ V\VWHP :KHQ XVLQJ VQRZ EORZHUV PDNH VXUH VQRZ LV QRW GLUHFWHG WRZDUGV YHQW WHUPLQDWLRQ DUHD Location of Vent Termination ,W LV LPSHUDWLYH WKH YHQW WHUPLQDWLRQ EH ORFDWHG REVHUYLQJ WKH PLQLPXP FOHDUDQFHV DV VKRZQ LQ WKLV PDQXDO 1010 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 11: Chimney Diagram

    RI WKH DSSOLDQFH ZKHQ WKH YHQWLQJ V\VWHP GRHV QRW PHHW WKHVH ‡ 2QO\ SHUPLWWHG LI YHUDQGD SRUFK GHFN RU EDOFRQ\ LV IXOO\ RSHQ UHTXLUHPHQWV RQ D PLQLPXP  VLGHV EHQHDWK WKH ÀRRU 1111 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 12: Termination Clearances

     $OO JUDYLW\ DLU LQWDNHV ZLWKLQ ¶  PP RI D WHUPLQDWLRQ FDS PXVW EH D PLQLPXP RI ¶  PP EHORZ WKH WHUPLQDWLRQ FDS Figure 2.11 - Termination clearances. 1212 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 13: Venting Requirements & Options

    WKH WZLVW ORFN RI WKH 'XUD9HQW FROODU $ JDV WLJKW VHDO ZLOO VWLOO EH PDGH EHWZHHQ WKH LQQHU DQG RXWHU SLSH VHFWLRQV 8VH D PLQLPXP RI WZR VFUHZV WR VHFXUH WKH 6/3 SLSH WR WKH VWDUWHU FROODU 1313 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 14 DQG VDIHW\ 5HSRUW GDPDJHG SDUWV WR \RXU GHDOHU UHJXODU EDVLV WR PDNH VXUH WKDW QR GHEULV LV LQWHUIHULQJ ZLWK WKH DLUÀRZ ,QVSHFW HQWLUH YHQWLQJ V\VWHP WR HQVXUH SURSHU IXQFWLRQ 1414 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 15 )RU 86 LQVWDOODWLRQV 7KH YHQWLQJ V\VWHP PXVW FRQIRUP ZLWK ORFDO FRGHV DQGRU WKH FXUUHQW 1DWLRQDO )XHO *DV &RGH $16, =1)3$  )RU &DQDGLDQ LQVWDOODWLRQV 7KH YHQWLQJ V\VWHP PXVW FRQIRUP WR WKH FXUUHQW &6$ % LQVWDOODWLRQ FRGH 1515 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 16 DQG FRQQHFW YHQW VHFWLRQV SHU LQVWDOODWLRQ LQVWUXFWLRQV '2 127 DOORZ YHQW WR VDJ EHORZ FRQQHFWLRQ SRLQW WR DSSOLDQFH Figure 3.5  6HFXULQJ 9HUWLFDO 3LSH 6HFWLRQV Figure 3.8  $OLJQ DQG 'LVDVVHPEOH 9HQW 6HFWLRQV 1616 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 17  PP LQ GLDPHWHU 127( :KHQ XVLQJ ÀH[ YHQW WKH RSHQLQJ ZLOO KDYH WR EH PHDVXUHG DFFRUGLQJ WR WKH ´  PP ULVH LQ ´  PP YHQW UXQ 1717 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 18 NOTE: $OZD\V LQVWDOO YHUWLFDO VLGH ZDOO KRUL]RQWDO YHQWLQJ ZLWK D ´ ULVH IRU HYHU\ ´ RI UXQ 9LQ\O 6LGLQJ :DOO Termination Cap Figure 3.13  +RUL]RQWDO 7HUPLQDWLRQ &DS RQ D 9LQ\O 6LGLQJ :DOO 1818 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 19: Vent Termination Below Grade

    Sheet Metal Collar Screws and Bracket :DOO 6FUHZV DQG $QFKRUV :DWHUSURRI 6HDO $URXQG 3LSH  3LSH :DOO 3ODWH Figure 3.14  8VH H[WHQVLRQ EUDFNHWV WR PRXQW VQRUNHO DJDLQVW UHFHVVHG ZDOO 1919 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 20 7ULP 3ODWH Planning Your Installation There are two basic types of installations: Figure 3.16 - 7\SLFDO 9HUWLFDO 9HQWLQJ &RQ¿JXUDWLRQ ‡ +RUL]RQWDO 7HUPLQDWLRQ )LJXUHV   ‡ 9HUWLFDO 7HUPLQDWLRQV )LJXUH  2020 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 21 $VVHPEOH WKH VOHHYH ZLWK WKH  VKHHW PHWDO VFUHZV VXSSOLHG $WWDFK WKH ¿UHVWRS SODWH WR WKH VOHHYH HQG ZLWK WKH KROHV )LJXUH  NOTE: 7KH ]HUR FOHDUDQFH VOHHYH Figure 3.18 LV UHTXLUHG LQ FRPEXVWLEOH ZDOOV RQO\ 2121 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 22 WR VHFXUH WKH MRLQW EXW DUH DFFHSWDEOH SURYLGHG WKH\ GR QRW SHQHWUDWH WKH LQQHU ZDOO RI WKH YHQW SLSH  6KHHW 0HWDO Screws Firestop Figure 3.22 - $VVHPEOH WKH ZDOO VOHHYH DQG ¿UHVWRS 2222 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 23 PDNH D VHDO EHWZHHQ WKH FDS DQG WKH ZDOO 7KH DUURZ RQ WKH YHQW FDS VKRXOG EH SRLQWLQJ XS (QVXUH SURSHU FOHDUDQFHV WR FRPEXVWLEOH PDWHULDOV DUH PDLQWDLQHG )LJXUH  2323 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 24 ERWWRP HGJH RI WKH FDS 7LJKWHQ DOO VFUHZV DQG PRXQW FDS ZLWK DOO IRXU  SLHFHV DWWDFKHG GLUHFWO\ RQWR WKH ZDOO ZLWK WKH IRXU    PP VFUHZV SURYLGHG )LJXUH  2424 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 25 SURWUXGLQJ WKURXJK WKH URRI 8VH D QRQKDUGHQLQJ VHDODQW EHWZHHQ WKH URRI ÀDVKLQJ DQG WKH URR¿QJ WR SUHYHQW ZDWHU OHDNDJH 6HFXUH WKH EDVH RI WKH URRI ÀDVKLQJ WR WKH URRI ZLWK URR¿QJ QDLOV 2525 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 26 ¿UVW ÀRRU LQFOXGLQJ FORVHWV DQG VWRUDJH VSDFHV LW PXVW EH HQFORVHG 7KH HQFORVXUH PD\ EH IUDPHG DQG FRYHUHG with sheet rock with standard construction materials, but Figure 3.38 UHTXLUHG FOHDUDQFHV WR FRPEXVWLEOHV PXVW EH PDLQWDLQHG 2626 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 27: General Maintenance

    FRUURVLRQ RI FDSV SLSH DQG ¿WWLQJV ,W PD\ EH FDXVHG E\ KDYLQJ H[FHVVLYH ODWHUDO UXQV WRR PDQ\ HOERZ DQG H[WHULRU SRUWLRQV RI WKH V\VWHP EHLQJ H[SRVHG WR FROG ZHDWKHU 2727 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 28 YHQWLQJ DQG FOHDUDQFH WR FRPEXVWLEOH UHTXLUHPHQWV FKLPQH\ XVLQJ &R/LQHDU 9HQW $GDSWHU RU D ÀH[ OLQHU 5HIHU WR which may vary from one appliance to another. )LJXUH  IRU DSSURYHG LQVWDOODWLRQV DQG YHQWLQJ FRPSRQHQWV UHTXLUHG 2828 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 29 ÀH[ SLSH WR WKH UHWUR FRQQHFWRU E\ VOLSSLQJ LW LQWR WKH   PP GLDPHWHU VOHHYH RQ WKH WRS VLGH RI WKH FRQQHFWRU 8VH WKUHH  VKHHW PHWDO VFUHZV WR DVVHPEOH WKHVH WZR SDUWV Figure 3.49 2929 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 30 0DVRQU\ :DOO connector may be completed with the section of black GLUHFW YHQW SLSH WRJHWKHU ZLWK DQ DGMXVWDEOH OHQJWK SLSH Retro VHFWLRQ Connector Masonry Bolts  1RW LQFOXGHG Figure 3.51 3030 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 31: Existing Masonry Chimney

    (Length as required) 4 ft. (1m) of 3 in. (76mm) Flex Liner Air Intake Section Co-Axial to Co-Linear Connector (Included in Chimney Liner Termination Kit) (Part 46DVA - GCL) Figure 3.54 3131 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 32  &RQQHFW WKH WKHUPRVWDW ZLUHV WR WKH YDOYH )LJXUH  TECHNICIAN. FOLLOW ALL LOCAL CODES. 7KLV FRPSOHWHV DVVHPEO\ RI WKH ,QWUHSLG VWRYH THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. 3232 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 33: Log Set Installation

    ORFDWLQJ SLQ RQ WRS ULJKW VLGH RI UHDU ORJ )LJXUH  3RVLWLRQ ORJ VR LW LV DQJOHG GRZQ WRZDUG WKH DUHD ZKHUH WKH IURQW WZR ORJV PHHW Figure 3.59  5LEV IRU /RJV 3333 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 34: Thermostat Connection

    NOTE: Always check for gas leaks with a mild soap and ZDWHU VROXWLRQ 'R QRW XVH DQ RSHQ ÀDPH IRU OHDN WHVWLQJ /LJKW WKH SLORW DFFRUGLQJ WR WKH GLUHFWLRQV LQ WKH 2SHUDWLRQ VHFWLRQ RI WKLV PDQXDO 3434 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 35 THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES. THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. 3535 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 36 IFT-RC400 REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 3.60  ,1'95,)7 :LULQJ 'LDJUDP 3636 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 37 NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. 3737 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 38: Operation

    DQ\ RI WKH ÀDPHV DSSHDU DEQRUPDO FDOO D VHUYLFH SHUVRQ Turn clockwise counterclockwise to decrease to increase flame height flame height Figure 4.3  )ODPH DGMXVWPHQW NQRE IRU 6,7 YDOYH 3838 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 39: Lighting Instructions

     3XVK LQ JDV FRQWURO NQRE VOLJKWO\ DQG WXUQ FORFNZLVH  7XUQ R DOO HOHFWULF SRZHU WR WKH VWRYH LI VHUYLFH LV WR EH WR ³2))  'R QRW IRUFH SHUIRUPHG  &ORVH FRQWURO DFFHVV SDQHO 3939 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 40 RU EORZLQJ KLJK FDXVLQJ DQG WKHUPRFRXSOH the pilot safety to drop out  3RVVLEOH EORFNDJH RI WKH  &KHFN WKH YHQW WHUPLQDO IRU EORFNDJH UHF\FOLQJ WKH ÀXH JDVHV vent terminal 4040 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 41: For Your Safety Read Before Lighting

    D. 'R QRW XVH WKLV DSSOLDQFH LI DQ\ SDUW RI LW KDV EHHQ XQGHU ZDWHU ,PPHGLDWHO\ FDOO D TXDOL¿HG VHUYLFH WHFKQLFLDQ WR LQVSHFW WKH DSSOLDQFH DQG WR UHSODFH DQ\ SDUW RI WKH FRQWURO V\VWHP DQG DQ\ JDV FRQWURO WKDW KDV EHHQ XQGHU ZDWHU 4141 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 42: Lighting Instructions (Ipi)

    For additional information on operating your Keep burner and control compartment clean. See installation and operating instructions Hearth & Home Technologies ¿ replace, please 593-913K accompanying appliance. refer to www.hearthnhome.com. 4242 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 43 ‡ 6OLGH WKH 215(027(2)) VZLWFK WR WKH 21 SRVLWLRQ NOTICE: Some functionality will be lost when using battery backup including remote control, fan, lights, or any other auxiliary functions that require household 110-120 VAC power 4343 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 44: Detailed Component Operating Instructions - Intellifireā„¢ Touch

     ,I PXOWLSOH FRQWURO RSWLRQV DUH LQVWDOOHG WKH ,)7(&0 ZLOO respond to the last command from the wired wall switch RU ,)75& 7KH ZLUHG ZDOO VZLWFK LV 127 DYDLODEOH LI D 3RZHU 9HQW LV XVHG 4444 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 45 ‡ 212)) )XQFWLRQV ‡ )ODPH KHLJKW DGMXVWPHQWV • Thermostat • Cold Climate Feature • Fan Speed 3OHDVH UHIHU WR WKH LQVWUXFWLRQV LQFOXGHG ZLWK WKH UHPRWH FRQWURO IRU PRUH GHWDLOHG RSHUDWLQJ LQVWUXFWLRQV 4545 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 46 DQG VXFFHVVIXOO\ WXUQV ÀDPH RQ ZLWKLQ  VHFRQGV ,I WKLV IDLOXUH DSSOLDQFH GLG QRW VWDUW 7U\ DJDLQ SHULRG RI DSSOLDQFH LQDFWLYLW\ SHUVLVWV FRQWDFW GHDOHU IRU VHUYLFH E\ SUHVVLQJ )ODPH 2Q *DV FRQWURO V\VWHP IDLOXUH 4646 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 47: Troubleshooting

    LV  RKPV ,I RSHQ RU VKRUWHG UHSODFH YDOYH &KHFN YDOYH KDUQHVV ZLUH FRQWLQXLW\ LI RSHQ UHSODFH SLQ KDUQHVV 3LORW ZRQ¶W OLJKW WKHUH LV QR QRLVH RU 6SDUN FRLO IDLOXUH 5HSODFH (&0 VSDUN  5HG *UHHQ /RFNRXW 4747 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 48 ÀDPH VHQVLQJ URG LV QRW FUDFNHG GDPDJHG RU ORRVH 'DPDJHG SLORW DVVHPEO\ Check resistance between tip of sense rod and IFT-ECM FRQQHFWRU VKRXOG EH OHVV WKDQ  RKP 5HSODFH SLORW DVVHPEO\ LI GDPDJH LV GHWHFWHG 4848 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 49: Burner, Pilot And Control Compartment

    IRU DERXW  WR  PLQXWHV WKH ÀDPH VKRXOG EH \HOORZ 127( 7KH W\SH RI LQVWDOODWLRQ YHQW V\VWHP FRQ¿JXUDWLRQ DQG ZLQG H HFWV PD\ FDXVH WKH ÀDPH SDWWHUQV WR YDU\ Figure 4.7  &RUUHFW SLORW DQG EXUQHU ÀDPH DSSHDUDQFH 4949 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 50: Annual System Inspection

    D FOHDQLQJ DJHQW IRUPXODWHG HVSHFLDOO\ IRU XVH RQ SRUFHODLQ HQDPHO VXUIDFHV CAUTION 7XUQ WKH SLORW R EHIRUH SDLQWLQJ $OORZ WKH KHDWHU WR FRRO FRPSOHWHO\ EHIRUH SDLQWLQJ Figure 5.2  5HOHDVH WKH ODWFKHV WR UHPRYH WKH JODVV IUDPH 5050 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 51: Gasket Replacement

    WKH JODVV SDQHO EDFN LQWR WKH VWHHO IUDPH 3LQFK WKH URXQGHG LQVLGHIDFLQJ JDVNHW PDWHULDO WR EXON LW XS  5HSODFH WKH JODVV IUDPH DQG IURQW SDQHO DV SUHYLRXVO\ GHVFULEHG 5151 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 52 DSSOLDQFH PXVW EH UHSODFHG LW PXVW EH UHSODFHG ZLWK type SF-2, 200°C wire or its equivalent. Chassis Ground RHEOSTAT / SNAPSTAT Optional Blower Kit Schematic Diagram MOTOR SNAPSTAT ON/OFF RHEOSTAT Figure 6.2  )DQ FLUFXLW 5252 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 53 IFT-RC400 REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 6.3  ,1'9,)7 :LULQJ 'LDJUDP 5353 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 54 INDVRCBSB (Classic Black) INDVRBMSB (Majolica Brown) (End Manufacturing Date: Mar 2019) INDVRBDSB (Bordeaux) INDVRBSSB (Biscuit) (End Manufacturing Date: Mar 2019) 24 25 23.2 23.1 Part number list on following page. 08/22 5454 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 55: Service Parts

    Brown Majolica SRV30004920 Classic Black 1306333A Biscuit SRV30003182 Bordeaux 30006716A Brown Majolica SRV30004830 Door, Control 30003945A Hinge, Control Door 1601670 Rear Shroud Assembly 30004132 Additional service parts on following page 5555 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 56 Magnet, Door 1408818 or silicone to attach Knob Extension, Hi/Lo 43D0095A .QRE ([WHQVLRQ 2Q2 43D0094A Tie Bracket Assembly 20012514 Right Burner Support Assembly 20012909K Additional service parts on following page 5656 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 57 Biscuit SRV30003214 Majolica SRV1302254-31 Classic Black 1302272A Bordeaux SRV30006721 Shelf Bracket Biscuit SRV30003215 Majolica SRV1302272-31 Conversion Kits Conversion Kit, NG to LP LPK-INDVR-SP Conversion Kit, LP to NG 20012910 5757 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 58 Beginning Manufacturing Date: Feb 2019 Gas Stove Ending Manufacturing Date: Active Intrepid Direct Vent/Rear Vent Gas Heater w/IFT Controls INDVR-IFT-CB (Classic Black) INDVR-IFT-BD (Bordeaux) Part number list on following page. 10/19 5858 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 59 Fan Cover Shroud 30004014 2166-302 Valve Propane 2166-303 Pilot Assembly SRV4602-300 SRV593-528 3LORW 2UL¿FH Propane SRV4602-301 2UL¿FH +RRG  SRV4604-317 2UL¿FH +RRG  30000336 Additional service parts on following page 5959 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 60 Conversion Kit SRV30007477 Propane to NG NGK-DXV-50 Regulator Propane SRVLPK-DXV-50 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 3A fuse, 3/4” long 6060 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 61  3RVLWLRQ WKH VKHOI DQG DGMXVW WKH EUDFNHWV VR WKH VKHOI RCB,RCMT TSST, RCST ¿WV FRUUHFWO\  7LJKWHQ WKH VFUHZV 5HIHU WR WKH LQVWUXFWLRQV LQFOXGHG ZLWK HDFK ZDUPLQJ VKHOI IRU FRPSOHWH LQVWDOODWLRQ SURFHGXUHV 6161 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 62: Warranty Policy

    1 year Burners, logs and refractory Limited Firebox and heat exchanger, FlexBurn® System 3 years Lifetime (engine, inner cover, access cover and fireback) 1 Year None All purchased replacement parts 6262 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 63: Warranty Conditions

    State to State. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE yWZ^^ t ZZ Edz ^W/&/ Ks &KZ d, WW>/ > WZKhd ^ 6363 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...
  • Page 64: Efficiency Ratings

    Based on CSA P.4.1-2015 EFFICIENCY RATINGS ENERGUIDE RATINGS D.O.E. STOVE EFFICIENCY MODEL PERCENTAGE $)8( 3(5&(17$*( INDVR Series   INDVR-IFT Series    0RXQWDLQ +RXVH 5RDG ‡ +DOLID[ 3$  ZZZYHUPRQWFDVWLQJVFRP 6464 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R27 • 06/23 3-90-30007474...

Table of Contents