Gasket Replacement; Inspect The Vent System Annually; Check The Gas Flame Regularly - Vermont Castings Intrepid INDVRBDSB Installation & Operating Manual

Direct vent gas heater
Hide thumbs Also See for Intrepid INDVRBDSB:
Table of Contents

Advertisement

DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and must be installed.
E. Gasket Replacement
The Intrepid DV Gas Heater uses a 'tadpole' type gasket to
seal between the glass panel and the frame. In time, this
gasket can become brittle and compressed and should be
replaced. New gasket is available from your dealer.
Shut off the gas supply and allow the stove to cool. Wear
safety goggles and a dust mask.
1. Remove the front, glass frame and glass panel, Figures
5.1 & 5.2. To remove the old gasket, use a razor blade
to separate the glass and gasket from the frame, and
to clean the glass of any remaining cement or bits of
gasket. Use a cold chisel if necessary.
2. Determine the correct length of gasket by laying it out
around the edge of the glass. Allow an extra 1 - 2" (25-
50mm). Mark the spot to be cut. Use a utility knife.
3. Starting on a long edge, remove about 6" of the
protective paper strip and apply the flat adhesive face
of the gasket around the outside-facing edge of the
panel. Continue around the panel, applying about 6" at
a time and being careful to not stretch the material. Do
not overlap the gasket ends, Figure 5.3.
4. Apply a thin bead of high temperature silicone rubber
sealant along the inside corner of the glass frame, all
around the perimeter. Place the flat gasketed side of
the glass panel back into the steel frame. Pinch the
rounded inside-facing gasket material to bulk it up.
5. Replace the glass frame and front panel as previously
described.
5252
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Vermont Castings • Intrepid DV-IFT Owner's Manual_R20 • 11/21
Figure 5.3 - Wrap the gasket material around the outside edge of the glass.
F. Inspect the Vent System Annually
Have the vent system inspected annually by a qualified
ST179
technician. Shut off the main gas supply before inspecting
glass gasket detail
the system. Both the inner exhaust pipe and the outer
11/99
combustion supply pipe must be checked to confirm that
they are unblocked and in good condition.
G. Check the Gas Flame Regularly
To ensure that the stove is operating properly, check the
flames periodically to confirm they match Figure 5.4. The
flames will be blue during the first 15-20 minutes of operation,
and will gradually turn to yellow after that.
Do not use your stove if the flame pattern differs from that
shown here. Contact your Vermont Castings dealer or a
qualified technician for help.
Figure 5.4 - Proper flame appearance
LG500
Intrepid log flames
7/07