E. Thermostat Connection
Intrepid logs
7/07
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge thermostat
wire to use for the length of lead required in your installation.
Thermostat
Wire / Gauge
18
16
14
1. Install the wall thermostat in the desired location and run
the wires to the stove location. Terminate these leads
with 1/4" female connectors.
2. Connect the thermostat or wall switch wires to the valve,
Figure 3.63.
SIT VALVE
Thermopile
Millivolt Thermostat
Figure 3.63- Install wiring to Thermostat before connecting to valve.
FP1622
SIT valve w/switch
3535
Top Log
Right Log
(optional):
Maximum Run
20 Feet
20 - 40 Feet
up to 60 Feet
Valve
Vermont Castings • Intrepid DV-IFT Owner's Manual_R20 • 11/21
!
Electrical connections should only be performed by a
qualified, licensed electrician. Main power must be off
when connecting to main electrical power supply or
performing service. All wiring shall be in compliance
with all local, city and state codes. The appliance, when
installed, must be electrically grounded in accordance
with local codes or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (latest edition) and
Canadian Electrical Code, CSA C22.1.
!
Label all wires before disconnecting when servicing
controls. Wiring errors can cause improper and dangerous
operation.
!
Do not connect wall switch to 110 V circuit.
!
Electrical connections should only be performed by a
qualified, licensed electrician. Main power supply must
be turned off before connecting fans to the main electrical
power supply or performing service.
!
Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox
for the type of fuel to be used. The Intrepid DV may be
converted from one gas to another using the appropriate Fuel
Conversion Kit listed in this manual under Replacement Parts.
In the U.S.; Gas connection should be made in accordance
with current National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Since some municipalities have additional local codes, be
sure to consult your local authority.
In Canada; consult the local authority and CSA-B149.1
installation code.
NOTE: Always check for gas leaks with a mild soap and
water solution. Do not use an open flame for leak testing.
Light the pilot according to the directions in the Operation
section of this manual.