D. Hearth Requirements
Hearth and Home Technologies does not recommend adhesive
based vinyl flooring due to thermal expansion. Floating-style
flooring (LVP - luxury vinyl plank or LVT – luxury vinyl tile) can be
used, but it will reach temperatures up to 110 °F in a room with
ambient temperature of 70 °F. Consult flooring specifications to
ensure compatibility.
When using LVP/LVT flooring, gas stoves require 6 inches of
alternative flooring in front of the stove before using LVP/LVT.
Whether the stove sits flush on the floor or is elevated on a
raised hearth, 6 inches of alternative flooring is required in front
of the stove or insert.
For all other flooring, continue to follow clearance to combustible
requirements in the installation manual.
NOTICE: Clearances that do not meet the minimum guidelines
could result in damage or buckling to the vinyl flooring and is
done at the installer's risk.
The Intrepid DV Heater can be installed on any type of rigid
flooring (e.g. hardwood, ceramic tile, brick, etc). When the
heater is installed on a carpeted surface, a metal or wooden
panel extending the full width and depth of the unit must be
used as the hearth. The purpose of the hearth is to prevent
the unit from sinking into the carpet surface and reducing the
required clearance to the underside of the unit. There are no
other hearth requirements.
E. Clearances to Combustibles
Parallel Installation: Minimum Clearance
4"
(102 mm)
Figure 2.3 - Parallel installation, minimum back and side clearances.
Corner Installation: Minimum Clearance
Parallel installation
Max. Vent
Length 24 in.
(610 mm)
2"
(51 mm)
Figure 2.4 - Corner installation, minimum corner clearances.
77
CAUTION
Max. Vent Length
24 in. (610 mm)
2-1/2"
(64 mm)
4"
(102 mm)
ST947
Intrepid
2" (51 mm)
01/19
St948
Vermont Castings • Intrepid DV-IFT Owner's Manual_R20 • 11/21
rear corner specs
01/19
Wall and Ceiling Clearances
4"
(102 mm)
Sidewall/
Trim
Figure 2.5 - Wall and Ceiling Clearances.
Mantel Clearances
Wall/Ceiling clearances
Combustible
Mantel or
Trim Materials
B
3" (75mm) Min.
A (Maximum)
9" (230 mm)
7-1/2" (190 mm)
ST382
6" (152 mm)
Pinnacle
4-1/2" (114 mm)
mantel clearances
3" (76 mm)
6/13/00 djt
1-1/2" (38 mm)
A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater
Figure 2.6 - Mantel Clearances
Alcove Clearances
4"
Min. Height = 69-3/4", Min. Width = 33-3/16", Max. Depth = 18-15/16"
Figure 2.7 - Alcove Clearances
9"
(230 mm)
Max. Mantel
Width
Refer to
2-1/2"
Fig. 2.6
(63 mm)
Rear Wall
St949
01/19
A
Noncombustible
Materials
B (Minimum)
10-1/2" (270 mm)
9" (230 mm)
7-1/2" (190 mm)
6" (152 mm)
4-1/2" (114 mm)
3" (76 mm)
45-1/2"
4"
3-90-30007474