3. Install the front left and right logs (Figure 3.23) by placing
them on the ribs shown in Figure 3.22. Make sure the logs
line up with the flat spots on the ember bed intended for
location purposes, Figure 3.23.
4. Install the left cross log by engaging the hole on the bottom
with the pin on the left side of the rear log. Set front side of
cross log on notch in ember bed, Figure 3.24.
5. Install the right cross log by engaging the hole on the
bottom with the pin on the right side of the rear log. Set
front edge of cross log on ember bed,Figure 3.24.
Front Left Log
Figure 3.23 - Front Logs
LG489
front logs
Rear Log
Left Cross Log
6/07
Front Left Log
Figure 3.24 - Completed Installation
LG490
all logs
6/07
2222
Ember Bed
Rib and Flat Spot
for Front Right Log
Front Right Log
Right
Cross Log
Front
Right Log
Ember Bed
Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19
E. Thermostat Connection
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge thermostat
wire to use for the length of lead required in your installation.
Thermostat
Wire / Gauge
18
16
14
1. Install the wall thermostat in the desired location and run
the wires to the stove location. Terminate these leads
with 1/4" female connectors.
2. Connect the thermostat or wall switch wires to the valve,
Figure 3.25.
SIT VALVE
Thermopile
Millivolt Thermostat
Figure 3.25- Install wiring to Thermostat before connecting to valve.
FP1622
!
SIT valve w/switch
Electrical connections should only be performed by a
qualified, licensed electrician. Main power must be off
when connecting to main electrical power supply or
performing service. All wiring shall be in compliance
with all local, city and state codes. The appliance, when
installed, must be electrically grounded in accordance
with local codes or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (latest edition) and
Canadian Electrical Code, CSA C22.1.
!
Label all wires before disconnecting when servicing
controls. Wiring errors can cause improper and dangerous
operation.
(optional):
Maximum Run
20 Feet
20 - 40 Feet
up to 60 Feet
Valve
WARNING
CAUTION
3-90-30007498