Intrepid® Direct Vent - Rear Vent Gas Heater

Burner Information

The appliance must only use the gas specified on the
rating plate, unless converted using a Vermont Castings
Fuel Conversion Kit. Refer to page 42 for correct Fuel
Conversion Kit for your stove model.
Coversion instructions are provided with each kit and on
page 34 of this manual.
THIS APPLIANCE SHOULD BE CONNECTED TO THE
GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE
TECHNICIAN. FOLLOW ALL LOCAL CODES.
THERE MUST BE A GAS SHUT-OFF BETWEEN THE
STOVE AND THE SUPPLY.

Complete the Assembly

• Open the swiveling latches (cams) on the top left and
right corners of the glass frame.
• Position the glass and frame against the firebox by
placing the bottom edge on the brackets on the bottom
face of the firebox.
• Swing the assembly against the firebox, and close the
latches firmly against the pins protruding from the firebox
top.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.
1. Apply wiring harness to the ON/OFF switch terminals
then insert into cut out on switch housing. The ON/OFF
switch will 'snap' into the cutout. (Fig. 55)
2. Run wires through cut out in side of shroud, under bot-
tom of rear shroud to valve.
3. Using supplied #10 x 1/2" screws, attach switch housing
over cut out opening in rear shroud.
4. Attach wires to valve terminals. (Fig. 56)
Wire
Harness
Switch As-
sembly
Screw
Fig. 55 Attach switch assembly to rear shroud.
28
Fig. 56 Attach switch wires to valve.
Grasp the Front Plate and lift it into position, engaging the
two steel tabs at the upper corners behind the adjacent
bosses in the Side Plates. (Fig. 57) Seat the Front against
the Sides so that the tabs at the bottom lip engage with the
notches in the edge of the stove base.
When properly installed, the bottom of the Front Plate
cannot be pulled away from the sides without also lifting
it up.
If you are installing optional Warming Shelves, do so now,
according to the instructions supplied with that kit.
Bottom Tabs Engage
Notch in Base
Fig. 57 Install stove front.

Thermostat Connection

Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.
Thermostat
Wire / Gauge
1. Install the wall thermostat in the desired location and run
the wires to the stove location. Terminate these leads
with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Fig. 56)
ST1120
This completes assembly of the Intrepid stove.

Install the Front Plate

ST228
attach switch
wires to valve
12/99
ST967
(Optional) R Models Only
Intrepid install front
7/07
Maximum Run
18
40 feet
20
25 feet
22
16 feet
ST228
ST967
20306761