Technical data

8.5 Liner

8.4

Design

Table 8-8
Design
Version
MAG 1100
Material
● Enclosure
Stainless steel AISI 316L
MAG 1100
(1.4404)
● Terminal box
Fibre glass reinforced polyamide
Standard
(not for Ex)
Option
Stainless steel AISI 316 (1.4436)
Stainless steel AISI 304 (1.4301),
● Fixing studs
Number and size to EN
1092-1:2001
● Gaskets
EPDM (max. 150 °C, PN 40
- Standard
(max. 300 °F, 600 psi))
- Option
Graphite (max. 200 °C, PN 40
(max. 390 °F, 600 psi))
PTFE (max. 130 °C, PN 25
(max. 270 °F, 300 psi))
● Pipe
● Stainless steel
connection
● Hastelloy
adapters:
● PVDF
DN 2, 3, 6 and
10 (1/12",
1/8", ¼" and
3/8")
8.5
Liner
Table 8-9
Liner
Version
MAG 1100
Ceramic
DN 2 and 3 (1/12" and 1/8"):
Zirconium oxide (ZrO
DN 6 to 100 (¼" to 4"):
Aluminum oxide Al
PFA
Reinforced PFA (not for Ex)
52
MAG 1100 HT
Stainless steel AISI 316L
(1.4404)
Stainless steel AISI 316 (1.4436) Fibre glass reinforced polyamide
Stainless steel AISI 304 (1.4301),
Number and size to EN
1092-1:2001
Graphite (max. 200 °C, PN 40
(max. 390 °F, 600 psi))
MAG 1100 HT
DN 15 to 100 (½" to 4"):
) (ceramic)
Aluminum oxide Al
2
O
2
3
MAG 1100 F
Stainless steel AISI 316L
(1.4404)
(not for Ex)
Stainless steel AISI 316 (1.4436)
Stainless steel AISI 304 (1.4301),
Number and size to EN
1092-1:2001
For ceramic:
FKM/FPM with stainless steel
insert (AISI 304/1.4301)
(-20 ... +150 °C (-4 ... +302 °F))
EPDM
(-20 ... +150 °C (-4 ... +302 °F))
For PFA:
EPDM
(-20 to +150 °C (-4 to +302 °F))
NBR
(-20 to +100 °C (-4 to +212 °F))
MAG 1100 F
Aluminum oxide Al
O
2
3
Reinforced PFA (not for Ex)
SITRANS MAG 1100/1100 F