Siemens SITRANS F Operating Instructions Manual page 54

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Technical data
8.8 Cable data
Standard applications
Table 8-12
Basic data
Max. cable loop resistance
Cable glands on sensor and
transmitter
Special applications, for example low conductivity or electrical noise
Table 8-13
Basic data
Ambient temperature
Cable parameter
54
Technical data, standard application cables
No. of conductors
Min. sqr. area
Shield
Max. capacitance
Media temperature:
< 100 °C (212 °F)
> 200 °C (392 °F)
M20x1.5 gland - Cable ø 5 to 13 mm (0.20 to 0.51 inches)
½ NPT gland - cable ø 5 to 9 mm (0.20 to 0.35 inches)
Technical data, special application cables
No. of conductors
Sqr. area
Shield
Color code
Outside color
Ext. diameter
Conductor
Isolation material
Flexible installation
Non-flexible installtaion
Capacity
Inductance
L/R
Coil cable
2
0.5 mm
2
Yes
N/A
40 Ω
6 Ω
Coil cable
Special electrode cable
3
1.5 mm
2
Yes
Brown, blue, black
Grey
7.8 mm
Flexible CU
PVC
-5 to +70°C
(23 to 158°F)
-30 to +70°C
(-22 to 158°F)
161.50 pF/m
0.583 μH/m
43.83 þH/Ω
SITRANS MAG 1100/1100 F
Operating Instructions, 08/2018, A5E03433301-AD
Standard electrode
cable
3
0.2 mm
2
Yes
350 pF/m
N/A
N/A
3
0.25 mm
2
Double
Brown, blue, black
Grey
8.1 mm
Flexible CU
PVC
-5 to +70°C
(23 to 158°F)
-30 to +70°C
(-22 to 158°F)
N/A
N/A
N/A

Advertisement