Mounting With A Threaded Type Adapter; Torques Values - Siemens SITRANS F Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Installing/Mounting

4.7 Torques values

4.6.3

Mounting with a threaded type adapter

To mount a MAG 1100 F with threaded type adapters, follow these steps:
1. Prepare the pipeline with a suitable fitting.
2. Assemble the sensor and adapters together with the gaskets.
3. Tighten the threaded connectors by using a C-spanner.
4.7
Torques values
Note
Torque values are calculated on the basis of use of gaskets.
DN
mm/inch
2 /
1
3 /
1
6 /
1
10 /
15 /
25 / 1
40 / 1
50 / 2
65 / 2
80 / 3
100 / 4
30
/
12
/
8
/
4
/
3
8
/
1
2
/
1
2
/
1
2
Nm
13
13
13
13
16
30
54
90
90
90
115