Nominal
L
size DN
3
6.14
4
7.32
A2 is 0.12 inch shorter than A1
1)
0.57 inch shorter when the stainless steel terminal box is used (Ex or high temperature 200 °C (392 °F) version)
2)
With transmitter MAG 5000 or MAG 6000 installed, weight is increased by approximately (1.8 lb). With MAG 6000 I weight
3)
is increased by 12.1 lb.
Table 8-21
MAG 1100 F built-in length
Nominal size DN
mm
inch
10
3/8
15
½
25
1
40
50
2
65
80
3
100
4
The total built-in length "L" is independent of the adapter type selected.
1)
SITRANS MAG 1100/1100 F
Operating Instructions, 08/2018, A5E03433301-AD
A
A
/A
B
1)
1
2
8.03
14.06
11.06
8.54
14.57
12.13
L
A
mm
99
99
113
126
154
165
200
225
B
D
2)
1
17.01
6.10
18.07
7.20
inch
3.90
3.90
4.45
4.96
6.06
6.50
7.87
8.86
Technical data
8.11 Dimensions and weight
D
(AI
O
)
D
(PFA)
i
2
3
i
3.15
3.19
3.94
3.94
L
1)
mm
inch
146
5.75
146
5.75
161
6.34
176
6.93
186
7.32
223
8.78
258
10.16
288
11.34
Weight
3)
15.0
22.0
61