Check at least every 6 months (twice a year):
– Electric connections of the unit - clean the oxidized parts and tighten the loosened ones. NOTE! You must
know correct tension torques before starting the repair of the joints.
– Clean the inner parts of the machine from dust and dirt e.g. with soft brush and vacuum cleaner.
Do not use compressed air, there is a risk that dirt is packed even more tightly into gaps of components!
Do not use pressure washing device!
Only authorized electrician shall carry out repairs to the machines.
Regular maintenance
Kemppi service repair workshops make regular maintenance according to agreement.
The major points in the maintenance procedure are listed as follows:
– Cleaning of the machine
– Checking and maintenance of the welding tools
– Checking of connectors, switches and potentiometers
– Checking of electric connections
– Metering units checking
– Checking of mains cable and plug
– Damaged parts or parts in bad connection are replaced by new ones
– Maintenance testing. Operation and performance values of the equipment are checked, and adjusted when
necessary by means of test equipment.

5. DISPOSAL OF THE MACHINE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment and
its implementation in accordance with national law, electrical equipment that has reached the end of its
life must be collected separately and returned to an environmentally compatible recycling facility. As
the owner of the equipment, you should get information on approved collection systems from our local
representative.
By applying this European Directive you will improve the environment and human health!

6. ORDERING NUMBERS

Units
Kempoweld 3200
Kempoweld 3200W
Wire feeder unit
Kempoweld WIRE 400
Accessories
KMW sync 2
MSD-1
P500 transport unit (feeder)
KV400 swing arm
KV400 50-1.5-GH
KV400 50-1.7-WH
Hub for wire reel
Branch cable KMP/Kempoweld
© KEMPPI OY
230 V / 400 V
621532002
230 V / 400 V
621632002
621740001
6219150
6185666
6185265
6185247
6260351
6260353
4289880
3151360
KEMPOWELD 3200, 3200W / 0543 – 11