Kemppi KEMPACT Operation Instructions Manual

Kemppi KEMPACT Operation Instructions Manual

Pulse 2800 mvu automotiv

Advertisement

Operation instructions • english
Bruksanvisning • norsk
KEMPACT™
PULSE 2800 MVU AUtoMotiVE
19101821
0709

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KEMPACT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kemppi KEMPACT

  • Page 1 19101821 Operation instructions • english 0709 Bruksanvisning • norsk KEMPACT™ PULSE 2800 MVU AUtoMotiVE...
  • Page 2: Table Of Contents

    4.2. RegUlaR maIntenanCe ..................13 4.3. DIsposal of the maChIne ................. 13 5. ORDERING INFORMATION ..................14 6. TECHNICAL DATA ...................... 15 7. TERMS OF GUARANTEE ................... 16  – Kempact™ pulse 800 mVu automotiVe / 0709 © Kemppi oy...
  • Page 3: Preface

    Additional information on Kemppi products and their use can be obtained from Kemppi or a Kemppi dealer. The specifications and designs presented in this manual are subject to change without prior notice.
  • Page 4: Before You Start Using The Unit

    2.4. CONNECTION TO THE MAINS SUPPLY The Kempact™ Pulse 2800 MVU Automotive is delivered with a five metre mains cable without a plug. Installation of the plug should be carried out only by a competent electrician. Power source recognizes the mains voltage automaticly.
  • Page 5: Wire Guide Tubes

    © Kemppi oy Kempact™ pulse 800 mVu automotiVe / 0709 – ...
  • Page 6: Installation Of Welding Gun

    Excessive pressure will cause the filler wire to flatten and damage its coating, as well as undue wear and tear of the feed rolls and friction damage.  – Kempact™ pulse 800 mVu automotiVe / 0709 © Kemppi oy...
  • Page 7: Adjustment Of Tightness Of Spool Brake

    Always fasten the gas cylinder securely in an upright position on a wall rack intended for the purpose or on a cylinder cart. Always close the cylinder valve after you have finished welding. © Kemppi oy Kempact™ pulse 800 mVu automotiVe / 0709 – 7...
  • Page 8: Operation

    The welding of very thin steelplates (0.5 to 0.7 mm) a - polarity might also work best for solid wire. 3.2.1. Changing the polarity - pole + pole Only a service shop authorised by Kemppi may change the polarity. 3.3. PANEL 8 – Kempact™ pulse 800 mVu automotiVe / 0709 © Kemppi oy...
  • Page 9: Choosing The Welding Method

    One press will revert to the material group and diameter display, a second will display the type number of the material and a third run through the gas consistency components one by one. © Kemppi oy Kempact™ pulse 800 mVu automotiVe / 0709 – 9...
  • Page 10: Adjustments, Display And Weld Data

    3.3.7. Mig extra functions Crater filling, 1-MIG and pulse MIG: Crater filling reduces welding mistakes caused by end craters.The welding power and end level can be changed using the SETUP-function. 10 – Kempact™ pulse 800 mVu automotiVe / 0709 © Kemppi oy...
  • Page 11: Use Of Gas Test

    Using the SETUP function, the user can change welding parameters which do not have their own panel functions. These parameters can be set separately for 1-MIG and Pulse MIG. SETUP settings are separate for each memory channel. © Kemppi oy Kempact™ pulse 800 mVu automotiVe / 0709 – 11...
  • Page 12 Disabling of gun remote control automatic identification Display reset 1...20 s time PRG INFO - feeld 1,2,3 selection Restore Restoring factory settings (off=no reset, pan=panel and setup all= also memory channels) 1 – Kempact™ pulse 800 mVu automotiVe / 0709 © Kemppi oy...
  • Page 13: Error Codes

    Note! Only a qualified electrician should remove or install the mains cable! 4.2. REGULAR MAINTENANCE KEMPPI -service workshops sign special service contracts with customers for regular maintenance. All parts are cleaned, checked and if necessary, repaired. The operation of the welding machine is also tested.
  • Page 14: Ordering Information

    Earth cable 35 mm² 6184311 Transport unit P20 6185261 Transport unit P250 6185268 Lift hook 4298180 Gas hose W000566 Wire spool pole 4289880 5 kg spool adapter 4251270 1 – Kempact™ pulse 800 mVu automotiVe / 0709 © Kemppi oy...
  • Page 15: Technical Data

    - 20 °C ...+ 40 °C for use Storage temperature - 40 °C ...+ 60 °C for use Degree of protection Ip23C The products meet conmormity reguirements for CE marking. © Kemppi oy Kempact™ pulse 800 mVu automotiVe / 0709 – 1...
  • Page 16: Terms Of Guarantee

    Guarantee repairs must be carried out only by an Authorised Kemppi Service Agent. Packing, freight and insurance costs to be paid by orderer. The guarantee is effected on the date of purchase. Verbal promises which do not comply with the terms of guarantee are not binding on guarantor.
  • Page 17 Telefax (08) 590 823 94 e-mail: sales.se@kemppi.com Tel (06033) 88 020 Telefax (06033) 72 528 KEMPPI NORGE A/S e-mail:sales.de@kemppi.com Postboks 2151, Postterminalen KEMPPI SP. z o.o. N – 3103 TØNSBERG Ul. Piłsudskiego 2 NORGE 05-091 ZA¸BKI Tel 33 34 60 00 Poland...

Table of Contents