4.2. EvERy SIXTh MONThS

The following maintenance operations should be carried out at least every sixth months:
• Clean off dust and dirt. Change the cooling liquid and wash up the pipes and water reservoir
with pure water.
• Check seals, cables and connections. Tighten, if necessary and replace defect parts.

4.3. TROUbLE ShOOTING

See also 3.2. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.
• Check water circulation.
• Check that there is enough free space behind the machine for cooling air circulation.
Text ERROR 5 on the KWF wire feeder panel
• Check the liquid hoses for damages.
• Remove any hose blockages.
• Check water circulation, clean the ventilation grilles and add liquid if needed.
For further information and assistance, contact your nearest Kemppi service workshop.

5. dISPOSAL OF ThE MAChINE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and returned to an
environmentally compatible recycling facility. As the owner of the equipment, you should
get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human
health!
6 – KWU10 / 0613