trOuBlesHOOting

Problem
The machine stops working.
Overheating indicator is lit, and
Err 4 is displayed.
Machine stops working.
Err 2 or Err 3 is displayed.
Machine stops working.
Err 43 is displayed.
Poor welding result
EN
Main switch indicator does not
switch on
* Contact Kemppi service in case of Err 2 and Err 3 without mains voltage cause.
5.

maintenanCe

5.1

regular maintenance

Check regularly the electrical connections of the machine. Clean any oxidised connections,
and tighten the loosened cable connections.
Let authorised Kemppi service workshop make periodic service to your machine. Appropriate
use and regular service guarantee trouble-free use of the machine. This allows you to avoid
interruptions and increase the productivity of the machine.
Remember that the machine may be repaired only by an electrical contractor or installer
NOTE!
authorised to perform such operations.
5.2

disposal of the machine

Do not dispose of electrical equipment with normal waste!
Electrical equipment that has reached the end of its life must be collected separately and
taken to an appropriate environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection centre, per the instructions of local authorities or a Kemppi representative. By
applying this you will improve the environment and human health.
20
HiArc M 400A, M 500A
Cause
The machine has overheated.
• Ensure that cooling air has unrestricted flow.
• The machine's duty cycle has been exceeded.
If no other damage is caused, the fan starts working and the machine recovers within a
couple of minutes.
If the problem persists, please contact Kemppi service representative.
The mains voltage is either too low (Err 2) or too high (Err 3). *
The machine recovers automatically, when the mains voltage is in the recommended
range (342 – 484 V).
The wire feeder motor is overloaded.
Check that you are using the right wire type and that the wire feed route is unobstructed.
Several factors affect the welding quality.
• Check wire feed calibration.
• Check that the earth return clamp is properly attached, the point of contact is clean and
that the cable and its connectors are intact.
• Check the voltage and wire speed settings on the control panel are correct for the given
wire size and type.
• Check that the shielding gas flow rate at the gun nozzle is correct.
• Check that the shielding gas is suitable for the filler wire used.
• Check that the wire feed is constant, and adjust if necessary.
• Check that the mains voltage is not too irregular.
The machine has no mains voltage
• Check the mains fuses
• Check the mains cable and the wall plug