Electronic Guide Light Egl - Leica TS10 User Manual

Hide thumbs Also See for TS10:
Table of Contents

Advertisement

Labelling
1.6.5
General
Safety Directions
CAUTION
Reflected beams aimed at reflecting surfaces
Potential hazards are not only related to direct beams but also to reflected
beams aimed at reflecting surfaces such as prisms, windows, mirrors, metallic
surfaces, etc.
Precautions:
Do not aim at areas that are essentially reflective, such as a mirror, or
which could emit unwanted reflections.
Do not look through or beside the optical sight at prisms or reflecting
objects when the laser is switched on, in laser pointer or distance meas-
urement mode. Aiming at prisms is only permitted when looking through
the telescope.
0016408_001
Model:
TS10
Art.No.:
1 2 3 4 5 6
Equip.No.: 1234567
Power: ..V
..W max
S.No.:
Leica Geosystems AG
1 2 3 4 5 6
CH-9435 Heerbrugg
Manufactured: 20XX
Made in Switzerland
Complies with FDA performance standards for laser products except for
deviations pursuant to Laser Notice No. 50, dated June 24, 2007.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
λ = 660nm
Pav = 4.8mW
tp = 400ps
IEC 60825-1:2014
0016409_001

Electronic Guide Light EGL

The Electronic Guide Light built into the product produces a visible LED beam
which emerges from the front side of the telescope.
The product described in this section, is excluded from the scope of
IEC 60825-1 (2014-05): "Safety of laser products".
The product described in this section, is classified as exempt group in
accordance with IEC 62471 (2006-07) and does not pose any hazard
provided that the product is used and maintained in accordance with
this user manual.
15