TIP: To check that powder is getting into the Feeder, look at the Debris Separator. You should see powder
moving through the window when the vacuum is running.
The vacuum automatically shuts off when the Feeder becomes full. See below.
NOTE - When the feeder is full, it has enough powder to complete a build that uses the entire " vertical
capacity of the Build Bed. Adding further powder provides no benefit, and risks overfilling the feeder.
Do not continue running the vacuum after the Feeder is Full message appears. If you continue to vac-
uum powder into the feeder, the LCD will display FEEDER POWDER LIMIT and the vacuum will be
disabled.
8. Remove the powder canister and return the vacuum hose to its stand.

5.6 Add Wash Fluid

To add wash fluid (cleaning solution), follow the steps below.
1. Open the top cover and then open the Service Station cover.
2. Hold down the top of the service station while pulling off the red cap.
3. Remove the red cap. Add cleaning solution until the tank is half full. Do not overfill.