Miscellaneous Problems; Vacuum Has Low/No Suction - 3D Systems ZPrinter 350 User Manual

Table of Contents

Advertisement

®
®
ZPrinter
350 / ZPrinter
Solution - Print Head
Troubleshoot using
Section 7.3, 'Print Head Errors/Weak
Solution - Motion Problems
Clean the Fast Axis Rails. See Section 3.3, 'Clean The Fast Axis Rails and Carriage'.

7.10 Miscellaneous Problems

7.10.1 Vacuum Has Low/No Suction

Explanation: This is usually an indication that the Debris Separator needs to be emptied and cleaned, or
that the vacuum hose is plugged or damaged. Less commonly, the printer may have been turned off and
on too quickly. Always wait 1 minute after turning power off before turning it on again.
Solution:
Debris Separator
Remove the Debris Separator and empty the contents into a waste receptacle.
Check that its gasket is not damaged. Also check that all four magnets are in place on the back of
the Separator. These magnets hold the Separator against the panel.
When you replace the Debris Separator, ensure that it is flush against the panel.
Vacuum Hose
Check the vacuum hose is not plugged with debris.
Check that the vacuum hose is not cut or torn.