200
Flat Line
Temperature
(Water is boiling)
System is calling for
heat, but the
temperature does
not rise at least 2°F
within 5 minutes.
201
Heater Open
System is calling for
heat, but the
temperature does
not rise at least 2°F
within 10 minutes.
This error is
disabled during
brewing and while
using the hot water
faucet.
202
Heater Short
System is not calling
for heat, but
temperature rises
more than 5°F.
255
Keypad Error
A switch was
pressed for more
than 45 seconds.
Utilize only qualified beverage equipment service technicians for service. A Service Company Directory may be
found on our web site, http://www.fetco.com. Companies listed as "Extractor Authorized" stock parts for these
models.
When changing the control board, check the software version on the chip. Example- V1.40. If the chip on the
replacement board has an older software version than the board being replaced, carefully remove the chip from the
old board and place it in the new board. Use a chip puller if one is available.
Brewer: The spray plates should be removed and cleaned periodically to remove hard water deposits. In areas
with extremely hard water, it may be necessary to do this weekly. Monthly cleaning may be sufficient in areas with
average water conditions.
LUXUS Dispensers :
Use the same techniques and products as you would use to clean any coffee urn. I.E.,
a) the sight gauge brush to scrub the gauge
b) urn brush for inside the dispenser
c) urn cleaner to clean the dispenser
d) stainless steel polish for the outside
e) hot water and towels for the faucet parts
Mercury relay is
Check mercury relay,
stuck closed, bad
check control board
output on control
output, or adjust
board, or
temperature for
temperature is set
altitude.
too high for altitude.
Heating element
Check and replace
failure.
heating elements if
necessary.
Possible mercury
Check mercury relay
relay stuck closed,
and control board.
or bad output on
control board.
Switch was held in
Clear error and try
too long, or switch
again. If error occurs
is stuck closed.
without switch being
pressed, replace
input board.

Service

Cleaning & Maintenance
Enter
programming
mode, then exit
programming
mode.
Enter
programming
mode, then exit
programming
mode.
Enter
programming
mode, then exit
programming
mode.
Enter
programming
mode, then exit
programming
mode.
13
Turn main power
switch off and
on.
Turn main power
switch off and
on.
Enter
programming
mode, then exit
programming
mode.
Turn main power
switch off and
on.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents