▣ ▣ MAGNETO NO-LOAD PERFORMANCE
Disconnect the three lead wires from the magneto
terminal.
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the AC voltage
between the three lead wires.
If the voltage is under the specified value, replace the
magneto with a new one.
Standard NO-load per-
for-mance of magneto
Pocket tester : 09900-25002
▣ ▣ REGULATOR / RECTIFIER
● Remove the rear fender. (Refer to page 7-5)
● Remove the regulator / rectifier.
● Using the pocket tester (× 1 MΪ
the resistance between the terminals in the follow-
ing table.
If the resistance checked is incorrect, replace the
regulator / rectifier.
� �
Tester probe
3�4
3�4
1�2
1�2
Pocket tester : 09900-25002
Over 70 V (at 5,000 rpm)
range), measure
Unit : MΪ
3�4
3�4
1�2
3�4
1�2
3�4
1�2
1�2
1�2
32 ㏀
1�2
1�2
1�2
1�2
1�2
32 ㏀
ELECTRICAL SYSTEM 6-8