Controlling G3Za Controllers Connected To Output Devices; Application - Omron EJ1 User Manual

Modular temperature controller
Hide thumbs Also See for EJ1:
Table of Contents

Advertisement

Controlling G3ZA Controllers Connected to Output Devices

3-4
Controlling G3ZA Controllers Connected to Output
Devices
3-4-1

Application

Heater plate
Heater plate
Heater plate
Heater plate
In this example configuration, G3ZA Multi-channel Power Controllers are used
to control the temperature in a 4-zone heater plate with a single control loop
by applying a fixed coefficient (slope) to the results of the EJ1's PID calcula-
tions.
NS5
Programmable Terminal
EJ1
TC4 + EDU
CN1
RS-485
EJ1 channel 1 Temperature Sensor
MV 14
EJ1 channel 2 Temperature Sensor
MV 24
EJ1 channel 3 Temperature Sensor
MV 34
EJ1 channel 4 Temperature Sensor
MV 44
• Up to eight G3ZA Controllers can be connected to the EJ1@-TC4 using
the special communications ports. It is not necessary to create a program
for communications between the EJ1 and G3ZA.
• Also, the G3ZA's internal parameters can be set to split a single EJ1
channel's control output into 4 branches (with the G3ZA-4H@03-FLK) or 8
branches (with the G3ZA-8A@03-FLK).
• A slope (coefficient) and offset value can be set for each branch output.
RUN
CJ1W-CIF11
RS-422A Converter
EJ1C-CBLA050 Cable
MV 11
MV 12
MV 13
MV 21
MV 22
MV 23
MV 31
MV 32
MV 33
MV 41
MV 42
MV 43
G3ZA
G3PA
Multi-channel
Power Solid-
Power Controllers
state Relays
Section 3-4
Up to 8 Units
Terminating
resistance