Other Functions (TC4 and TC2)
102
Bus Input Assignments (TC4/TC2)
Bus input 1
Bus input 2
• Bus inputs 2 and 3 can be set in the same way.
• Channels 3 and 4 are supported only by the TC4.
Settable
parameters
All channels
Disabled
Bank (bit 0)
Bank (bit 1)
Stop (0)/Run (1)
Run (0)/Stop (1)
Auto (0)/Manual (1)
Local SP (0)/Remote SP (1)
Bus Output Assignments (TC4/C2)
Bus input 1
Bus input 2
• Bus inputs 2 and 3 can be set in the same way.
• Channels 3 and 4 are supported only by the TC4.
Settable
parameters
All channels
Disabled
Temperature Controller Error
All Alarm OR
All Alarm AND
Alarm 1 to 3 OR
Alarm 1 to 3 AND
Input Error OR
RSP Input Error OR
HB (Heater Burnout) Alarm OR
HS (Heater Short) Alarm OR
OC (Heater Overcurrent) Alarm OR
Event Input 1 to 4
Bus Input 1 to 3
Note Temperature Controller Error
The Temperature Controller Error output will turn ON when an bit
between bit 0 and bit 13 in the Device A Status is ON. It can be
used to output EJ1 error status. Refer to Status Lists on page 209
for details on Device A Status.
Variable type
F2/B2
Bus Input 1 to 3 Assignment
Bus Output 1 to 3 Assignment
Conditions for use
No special conditions
Bus input 3
Channel 4
Bank (bit 0)
Channel 3
Bank (bit 1)
Bank (bit 0)
Channel 2
Stop (0)/Run (1)
Bank (bit 1)
Bank (bit 0)
Channel 1
Run (0)/Stop (1)
Stop (0)/Run (1)
Bank (bit 1)
Bank (bit 0)
Auto (0)/Manual (1)
Run (0)/Stop (1)
Stop (0)/Run (1)
Bank (bit 1)
Local SP (0)/Remote SP (1)
Auto (0)/Manual (1)
Run (0)/Stop (1)
Stop (0)/Run (1)
Local SP (0)/Remote SP (1)
Auto (0)/Manual (1)
Run (0)/Stop (1)
Local SP (0)/Remote SP (1)
Auto (0)/Manual (1)
Local SP (0)/Remote SP (1)
Bus input 3
Channel 4
Alarm 1 to 3
Channel 3
All Alarm OR
Alarm 1 to 3
Channel 2
All Alarm AND
All Alarm OR
Alarm 1 to 3
Channel 1
Input Error
All Alarm AND
All Alarm OR
Alarm 1 to 3
RSP Input Error
Input Error
All Alarm AND
All Alarm OR
Heater Burnout Alarm
RSP Input Error
Input Error
All Alarm AND
HS Alarm
Heater Burnout Alarm
RSP Input Error
Input Error
OC Alarm
HS Alarm
Heater Burnout Alarm
RSP Input Error
Bank (bit 0)
OC Alarm
HS Alarm
HB (Heater Burnout) Alarm
Bank (bit 1)
Bank (bit 0)
OC Alarm
HS (Heater Short) Alarm
Stop (0)/Run (1)
Bank (bit 1)
Bank (bit 0)
OC (Heater Overcurrent) Alarm
Run (0)/Stop (1)
Stop (0)/Run (1)
Bank (bit 1)
Bank (bit 0)
Auto (0)/Manual (1)
Run (0)/Stop (1)
Stop (0)/Run (1)
Bank (bit 1)
Local SP (0)/Remote SP (1)
Auto (0)/Manual (1)
Run (0)/Stop (1)
Stop (0)/Run (1)
Local SP (0)/Remote SP (1)
Auto (0)/Manual (1)
Run (0)/Stop (1)
Local SP (0)/Remote SP (1)
Auto (0)/Manual (1)
Local SP (0)/Remote SP (1)
Parameter name
TC4: 0 to 132
(Common)
TC2: 0 to 69
TC4: 0 to 150
(Common)
TC2: 0 to 87
Section 4-7
Setting range
Default
0
0