Programless Communications
DM Area Value
D00000
0000
Read Response Bits
D00001
0001
Setting Change Response Bits
D00500
0000
Read Request Bits
D00501
0001
Setting Change Request Bits
D00502
0000
Operation Command Request Bits
D00503
0000
Operation Command Code
D00504
0064
Channel 1 Set Point
D00505
0064
Channel 2 Set Point
Checking Operation
with MELSEC-Q/
QnAS Series
1,2,3...
Meaning
If Not Operating Correctly
Check the following items if the operation is incorrect.
• Are the wiring and settings correct?
• Was the power cycled once the EJ1 and PLC settings were completed?
(The EJ1 settings are enabled only after the EJ1 is reset.)
This section describes how to check operation for the configuration shown
below.
MELSEC-Q/QnAS Series
1. Connect the EJ1 and PLC.
Connect the EJ1@-HFU and Serial Communications Unit as shown in the
following diagram.
Procedure step number and confirmation item
Step 3: Set to 0001 by the system.
Step 2: Set from PLC user program.
Step 1: Set from PLC user program.
Step 1: Set from PLC user program.
ch1
RS-232C
Section 5-1
EJ1
HFU
TC
EDU
Unit
Unit
No. 0
No. 1
113