If the actual operating conditions differ from things mentioned above, the inspection cycles may change
accordingly.
Replacement Guidance
Parts replacement cycles depend on the actual operating conditions and how the equipment has been
used. Defective parts should be replaced or repaired immediately.
Prohibited
Equipment
Amplifier
Aluminum
electrolytic
capacitor on the
print board
Motor
Troubleshooting
The motor does not rotate.
[Check Points]
Dismantling for inspections or repairs should be done by our company (or
our sales agents).
Standard
replacement
Part
cycles (hour)
Smoothing
about 5 years
condenser
about 5 years
Bearing
3 to 5 years
(20 to 30 thousand
hours)
Oil seal
5000 hours
Encoder
3 to 5 years
(20 to 30 thousand
The replacement cycles shown here are
just only for reference. If any part is found
defective regardless of the standard
replacement cycles, immediately replace it
hours)
with a new one.
- 87 -