S-link gateway controller for devicenet

Advertisement

INSTRUCTION MANUAL
Sensor & Wire-saving Link System S-LINK
S-LINK Gateway Controller for DeviceNet
SL-GU1-D
© Panasonic Industrial Devices SUNX Co., Ltd. 2012 MJE-SLGU1D No.0037-73V

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic SL-GU1-D

  • Page 1 INSTRUCTION MANUAL Sensor & Wire-saving Link System S-LINK S-LINK Gateway Controller for DeviceNet SL-GU1-D © Panasonic Industrial Devices SUNX Co., Ltd. 2012 MJE-SLGU1D No.0037-73V...
  • Page 2: Power Supply

    1. INTRODUCTION Thank you very much for using Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a con- venient place for quick reference. Never use this product in a device for personnel protection.
  • Page 3: Functional Description

    Status data is not added to the DeviceNet transmission data. ‡ If the power supply of SL-GU1-D is switched on when the system set button is pressed, the setting of the S-LINK system side output in case of upper network abnormality is System set button changed.
  • Page 4: Net Status

    Description Function Transmission indicator It blinks to indicate the synchronization signal used for signal transmission / reception. (SEND) (Green) Error indicators They light up according to the type of error. (ER1, 3, 4) (Red × 3) (Refer to “14. ERROR INDICATORS.”) S-LINK terminal block S-LINK system’s signal line and power supply are connected.
  • Page 5: Mounting And Connection

    Engage the hooks on the upper part of the adapter onto the DIN rail and press the lower part of SL-GU1-D to mount it on the DIN rail. To dismantle, pull down the stopper on the lower part of the adapter with a screwdriver, etc.
  • Page 6: Terminal Arrangement

    Wires Brown Blue White Black Brown Mounting screws Blue White Connection to “SL-GU1-D” Black DC power supply 24V DC±10% Be careful not to cause short-circuit with any adjacent terminal. <DeviceNet terminal block connector> DeviceNet terminal block connector Wires V- (Black)
  • Page 7: Selection Of Power Supply

    S-LINK units and the I/O devices. 6. WHEN THE POWER IS INITIALLY ON Error 4 (ER4) may occur when the power of SL-GU1-D is initially turned on. In this case, press the system setting button to set the S-LINK address.
  • Page 8: Setting Procedure

    7. SETTING PROCEDURE Make sure to perform setting operations 2, 3 in the power supply off condition. 1. S-LINK system side output setting in case of upper network failure Perform the S-LINK system side output setting for the case when data exchange cannot be done with the master as per “8.
  • Page 9 Output A of SL-GU1-D, it is easier to specify the cable disconnection loca- tion if the smallest address is assigned to the S-LINK unit nearest to Output A of SL-GU1-D, and then the addresses are assigned in the ascending order.
  • Page 10 SL-GU1-D cannot recognize the address of booster SL-BS1A. ‡ When the system set button is pressed, the number of connected S-LINK units recognized by SL-GU1-D LV ¿UVW GLVSOD\HG LQ KH[DGHFLPDO IRUP LQ WKH DGGUHVV GLVSOD\ DQG WKHQ WKH character “ ” rotates in the clockwise direction.
  • Page 11 12. CABLE DISCONNECTION DETECTION SL-GU1-D monitors the S-LINK system side signal transmission line, and in case cable discon- nection, or a fault in an S-LINK unit, occurs, the address of the faulty unit is displayed in hexa- decimal form. However, in case of a multi-channel S-LINK XQLW RQO\ WKH DVVLJQHG ¿UVW DG- dress is displayed.
  • Page 12: Error Indicators

    13. ERROR ADDRESS DISPLAY In case Error 4 indicator (ER4) lights up, it is possible to display the addresses of all the S-LINK units where the error occurs by the following procedure. However, in case of a multi-channel S-LINK XQLW RQO\ WKH DVVLJQHG ¿UVW DGGUHVV LV GLVSOD\HG (Valid only for devices having the mark) 3UHVV WKH V\VWHP VHW EXWWRQ DIWHU FRQ¿UPLQJ WKDW WKH PRGH VZLWFK 02'( LV VHW WR ³&+.´...
  • Page 13: Memory Map

    = “ABDTDEV” I/O byte No. setting ‡ When SL-GU1-D is incorporated into the DeviceNet system, the data exchange size on De- viceNet is determined by the setting on the S-LINK system side. ‡ Secure a memory area on the master depending on the total No. of I/O, I/O setting and sta- tus setting of the S-LINK system side.
  • Page 14: Status Data

    07H in the transmission I/O data area. “1” is written in Bit 0 for the output to be ON, and “0” is written for the output to be OFF. Note: Even if the S-LINK system I/O assignment is not continuous, the I/O data area of SL-GU1-D is as- signed continuously.
  • Page 15: Response Delay Time

    ‡ Input response delay time of S-LINK system = S-LINK input unit processing time + S-LINK system transmission time + SL-GU1-D pro- cessing time ‡ Output response delay time of S-LINK system = SL-GU1-D processing time + S-LINK output unit processing time + S-LINK system trans-...
  • Page 16: Specifications

    Notes: 1) The current consumption is the sum of the maximum current (D-G line only) supplied to the connected S- LINK units and the current consumption of SL-GU1-D. 2) The allowable through current is the maximum value of the sum of the above mentioned current consump- tion and the current consumed by the users’...
  • Page 17 Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany <From July 1 ,2013> Panasonic Marketing Europe GmbH Panasonic Testing Center Winsbergring 15, 22525 Hamburg,Germany <Conditions in use for CE marking conformity> The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 and the following condition must be met to conform to that standard.
  • Page 18 (2) Any Products found to be defective must be shipped to Panasonic Industrial Devices SUNX with all shipping costs paid by Purchaser or offered to Panasonic Industrial Devices SUNX for inspection and examination.