Hardware description
3.2 Interface description
3.2.4

Interface (S2): PROFIBUS address

(SINUMERIK 802D sl)
For 802D sl, the PROFIBUS address of the ADI4 DP slave can only be set to the value 15 or 16
Setting
Table 3-4
Note
A newly set PROFIBUS address will only come into effect after power OFF/ON.
3.2.5

Interface (X3): Analog setpoint interface

Connection
50-pin sub D connector
Pin assignment
Table 3-5
Pin
1
2
3
4
5-13
14
24
Meaning of switch S2
Switches
1
2
3
4
5
6
7
8
Pin assignment: Analog setpoint interface (X3)
Designation
SW1
BS2
SW3
BS4
-
RF1_1
Meaning
PROFIBUS address: 2
PROFIBUS address: 2
PROFIBUS address: 2
PROFIBUS address: 2
PROFIBUS address: 2
PROFIBUS address: 2
PROFIBUS address: 2
Not used
Type
1)
VO
Setpoint of Axis 1 (±10 V)
3)
VO
Reference for setpoint of Axis 2
VO
3)
Setpoint of Axis 3 (±10 V)
VO
Reference for setpoint of Axis 4
-
-
K
"Drive enable" of Axis 1, Relay Contact 1
2)
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
= 1
0
= 2
1
= 4
2
= 8
3
4
= 16
= 32
5
= 64
6
Function
Equipment Manual, 07/2017, A5E33446849B