Mitsubishi Electric FDF100VSXVD Technical Manual page 135

Hide thumbs Also See for FDF100VSXVD:
Table of Contents

Advertisement

DIP switch setting list (Outdoor unit)
(1) Control PCB
Model FDC71VNX
Switches
Defrost condition
SW3-1
SW3-2
Snow protection control
Model selection
SW3-3
Defrost prohibition time
SW3-4
SW4-1
Model selection
Model selection
SW4-2
SW4-3
Reserved
Spare
SW4-4
Model selection
SW5-1
SW5-2
Model selection
Test run SW
SW5-3
Test run mode
SW5-4
SW7-1
Spare
Antifrost control
SW7-2
SW7-3
Spare
Reserved
SW8-1
Spare
SW8-2
SW8-3
Spare
Pump down operation
SW9
Models FDC100,125,140VNX,100,125,140VSX
Switches
Pump down operation
SW1
JSW1-1
JSW1-2
Model selection
JSW1-3
JSW1-4
Defrost condition
SW3-1
SW3-2
Snow protection control
Test run SW
SW3-3
SW3-4
Test run mode
Model selection
SW4-1
Model selection
SW4-2
SW4-3
Reserved
Reserved
SW4-4
Reserved
SW5-1
SW5-2
Reserved
Reserved
SW5-3
SW5-4
Reserved
Antifrost control
J5
J7
Outdoor fan control when ducting
Table 1: Outdoor unit model selection with JSW1-1-JSW1-4 and SW4-1-SW4-2
100VNX 100VSX 125VNX 125VSX 140VNX 140VSX
JSW1-1
0
0
JSW1-2
0
0
JSW1-3
0
0
JSW1-4
0
0
SW4-1
1
1
SW4-2*
1
0
(2) Inverter PCB
71VNX
Switches
Single phase models
JSW10-1
OFF
JSW10-2
OFF
JSW10-3
OFF
JSW10-4
OFF
JSW11-1
ON
JSW11-2
ON
JSW11-3
ON
JSW11-4
ON
* When check i ng inv e rter PCB of FDC71
(Regarding the check i ng method of inv e rter PCB with inv e rter check e r, refer to page 141 for details)
Description
Normal*/Cold region
Normal*/Snow protection
Cooling only/Heat pump*
ON: 37min*/OFF: 45min
Domestic/Overseas*
3-phase/Single phase*
Capacity
Capacity
Normal*/Test run
Cooling*/Heating
Valid*/Invalid
Normal*/Pump down
* Default setting
Description
Normal*/Pump down
Normal*/Cold region
Normal*/Snow protection
Normal*/Test run
Cooling*/Heating
Domestic/Overseas*
3-phase/Single phase
Valid*/Invalid
Normal*/Hi tap
* Default setting
0: OFF
1:ON
1
1
0
0
0
0
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
0
1
0
* 3-phase: OFF/Single phase: ON
100, 125, 140VNX
100, 125, 140VSX
Single phase models
3-phase models
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
〜 140 models with inv e rter check e r, turn JSW10 - 4 ON.
-
Default setting
Normal
OFF
OFF
Normal
Heat pump
OFF
37min.
ON
ON
Overseas
Single phase
ON
OFF
OFF
OFF
OFF
Normal
OFF
Cooling
OFF
OFF
Valid
OFF
OFF
OFF
OFF
OFF
Normal
OFF
Default setting
Normal
OFF
As per model
Normal
OFF
OFF
Normal
Normal
OFF
OFF
Cooling
Overseas
ON
As per model
OFF
OFF
OFF
OFF
OFF
OFF
Valid
With
With
Normal
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
134
-
'11 • PAC-T-160
Remarks
Keep OFF
Keep ON
Keep ON
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Remarks
See table 1
See table 1
See table 1
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Keep OFF
Keep OFF