Accessing The Bootware Operation Submenu; Skipping Console Login Authentication; Table 20 Bootware Operation Submenu Options - H3C SECPATH 5080F-CMW710-R9628P2414 Release Notes

Table of Contents

Advertisement

To start the device with the factory-default configuration:
6.
Enter 6 in the EXTEND-BOOTWARE menu and press Enter.
Enter your choice(0-9): 6
Flag Set Success.
7.
Follow the system instruction to complete the task.
If password recovery capability is enabled, the device uses the factory-default configuration
instead of the configuration file for the next startup.
If password recovery capability is disabled, first enable the capability from the CLI, and then
reboot the device to access the EXTENDED-BOOTWARE menu.
Password recovery capability is disabled. To perform this operation, first enable
the password recovery capability using the password-recovery enable command in CLI.

Accessing the BootWare Operation submenu

Enter 7 in the EXTEND-BOOTWARE menu and press Enter.
Enter your choice(0-9): 7
=========================<BootWare Operation Menu>==========================
|Note:the operating device is sda0
|<1> Backup Full BootWare
|<2> Restore Full BootWare
|<3> Update BootWare By Serial
|<4> Update BootWare By Ethernet
|<0> Exit To Main Menu
============================================================================
Enter your choice(0-4):

Table 20 BootWare Operation submenu options

Option
<1> Backup Full BootWare
<2> Restore Full BootWare
<3> Update BootWare By Serial
<4> Update BootWare By Ethernet
<0> Exit To Main Menu

Skipping console login authentication

To perform this task, make sure password recovery capability is enabled. If the capability is disabled,
you cannot perform this task.
This is a one-time operation and takes effect only for the reboot after you perform this task.
To enable the device to load the next-startup configuration file with the console login password
ignored:
8.
Enter 8 in the EXTEND-BOOTWARE menu and press Enter.
Enter your choice(0-9): 8
9.
Follow the system instruction to complete the task.
If password recovery capability is enabled, the device clears the password for user privilege
change.
Description
Back up the entire BootWare image.
Recover the entire BootWare image.
Upgrade the BootWare image through the serial port.
Upgrade BootWare through the management Ethernet port.
Return to the EXTEND-BOOTWARE menu.