Altronix Trove Mercury kits are pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/charger
and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to four (4) doors in a single enclosure.
Altronix
Model
Number
5A/
T1MK14
3.0
250V
5A/
T1MK14D
3.0
250V
5A/
T1MK14S
3.0
250V
5A/
T1MK14SD
3.0
250V
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two (2) keyholes in the enclosure. Install two upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two upper screws; level and secure.
Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the
enclosure's upper keyholes over the three upper screws. Install the two lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model T112 or equivalent) in desired location, opposite hinge.
Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Position Mercury access controller modules over corresponding spacers and depress onto
snap on spacers, Fig. 2, 3, pg. 3, 4.
5. Refer to the ULXB Power Supply/Charger Installation Guide for AL400ULXB2,
and corresponding Sub-Assembly Installation Guide for ACM4(CB), PDS8(CB)
and VR6 for further installation instructions.
6. Mount backplane to enclosure with hardware.
Hardware:
Snap On Spacer
- 2 -

Configuration Chart:

Nominal
DC
Output
Maximum Supply
Current for Outputs
on Power Supply board
and ACM4/ACM4CB
Access Power
Controller's outputs
15A/
20.28-
24VDC @ 3.6A
32V
26.4
15A/
20.28-
24VDC @ 3.6A
32V
26.4
15A/
20.28-
24VDC @ 3.6A
32V
26.4
15A/
20.28-
24VDC @ 3.6A
32V
26.4

Installation Instructions:

|
5/16" Pan Head Screw |

Overview:

(A)
4
4
4
4
Lock Nut
10A/
3A/
2.5
250V
250V
10A/
2.0
2.0A
250V
10A/
3A/
2.5
250V
250V
10A/
2.0
2.0A
250V
Edge of
Enclosure
Tamper Switch
(included)
Trove1 Mercury ULXB Kits Installation Guide
10A/
3A/
250V
250V
10A/
2.0A
250V
Fig. 1
Enclosure
To Access Control Panel or
UL Listed Reporting Device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T1MK14 and is the answer not in the manual?

This manual is also suitable for:

T1mk14dT1mk14sT1mk14sdTrove t1mk14Trove t1mk14sTrove t1mk14d ... Show all

Table of Contents